Linear manual WO15Z-1 Duplex Receptacle, Installation, Including WO15Z-1 to the Network

Page 1

WO15Z-1

GREEN

ALWAYS POWERED OUTLET

CONTROLLED OUTLET

Radio Frequency Controlled, 120 VAC, 15A, Duplex

Receptacle, Series 300

GROUND

TOTAL LOADS MUST NOT EXCEED 15 AMPS @ 120 VAC

(INCLUDES ALL LOADS PLUGGED INTO THE RECEPTACLE)

WHITE

NEUTRAL

BLACK

LINE 120 VAC

TOTAL LOADS MUST NOT EXCEED 15 AMPS @ 120 VAC (INCLUDES ALL LOADS PLUGGED

INTO THE RECEPTACLE

NOTE: This module must be “included in the Network” only where it will be permanently installed. The proper operation of this node in the mesh network is dependent on it knowing its location with respect to other nodes. You cannot “test bench” confi gure this module, then install.

WO15Z-1 DUPLEX RECEPTACLE

Linear’s family of Z-Wave certifi ed wireless lighting controls (switches, dimmers, outlets and plug-in modules) brings a new level of intelligent wireless capability to commercial and residential environments.

The Z-Wave wireless protocol is an international wireless standard for remote home automation, security and other applications. Embedded in each device, the Z-Wave smart chip enables two-way RF communication among hundreds of Z-Wave enabled devices, allowing products and services from multiple manufacturers to work seamlessly.

Linear Z-Wave products are easy to install, and allow dealers to create an integrated wireless network with nearly limitless expansion and interoperability with security and health monitoring systems, energy management, home entertainment, appliances, and more.

As part of a Z-Wave network, the WO15Z-1 will also act as a wireless repeater to insure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller.

DANGER! SHOCK HAZARD. Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. It is recommended that a qualifi ed electrician perform this installation. Make sure the total load controlled does not exceed 1800 watts. For indoor use only. Retain instructions for future use.

INSTALLATION

Wire this receptacle in place of a current receptacle according to the diagram above. Use copper wire only, or equivalent.

INCLUDING WO15Z-1 TO THE NETWORK

STEP 1. Prepare the Controller to include a unit to the network, by adding it to a group (method of adding a node to the network). Refer to controller instructions.

STEP 2. The WO15Z-1must be in its permanently installed location. Tap the button on the face of the WO15Z-1 once when your controller indicates (to include in the network).

1

STEP 3. You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.

NOTE: If you have trouble adding the WO15Z-1 to a group it may be that the Home ID and Node ID were not cleared from it after testing. You must first “RESET UNIT” with your controller to remove it from the network.

Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a group, it functions as a repeater only. “RESET UNIT” removes it from the network

Receptacle Configuration

The WO15Z-1 Receptacle controls the ON and OFF of a load connected to the controlled outlet (See Wiring Diagram for identification).The other outlet remains powered all the time. A button on the face of the receptacle is used to add the module to the wireless network and be controlled from the wireless controller. With the Wireless Controller, the WO15Z-1 Receptacle can be turned ON and OFF remotely, and can be included in groups that operate at the same time (a group can be a single module), and in scenes that set a lighting mood.

Local ON and OFF

When the button on the face of the WO15Z-1 is pressed, the power to the controlled outlet will turn on. When the button is pressed again, the controlled outlet will turn off.

Child Protection

The WO15Z-1 controlled outlet can be set in a child protect mode by the Wireless Controller. When this mode is active, a user will have to press the button on the face 3 times rapidly to activate the attached load. The module operates normally when controlled by the Wireless Controller.

Other Functions

The button on the face of the WO15Z-1 Receptacle can be used to carry out inclusion (add to a group), association (operate simultaneously with other nodes), exclusion (remove from group) or reset (remove from network). The WO15Z-1 has a blue indicator LED. This LED will turn on when the controlled outlet is on and will turn off when the controlled outlet is off. However, its behavior can be confi gured as a “night light” (LED ON when the controlled outlet is off). See Confi guration section below on how to do it.

Image 1
Contents WO15Z-1 Duplex Receptacle InstallationIncluding WO15Z-1 to the Network Configuration WarrantyFCC Notice