Bryant 564B manual Unit Support, Regular Dealer Maintenance, Warranties, For the Record

Page 3

WARNING: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury and/or death.

Disconnect all electrical power to the indoor air handler or furnace before removing access panels to perform any maintenance. Disconnect power to both the indoor and outdoor units. Note: There may be more than 1 electrical disconnect switch.

CAUTION: PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.

Although special care has been taken to minimize sharp edges in the construction of your unit, to avoid injury be extremely careful when handling parts or reaching into the unit.

A. Check the Air Filter

A dirty air filter will cause excessive strain on the compressor and blower motor. This can cause the components to overheat and automatically shut down. In the worst case, the components will fail and need to be replaced. To avoid inefficient or failed operation of your unit, CHECK THE FILTER(S) EVERY 3 MONTHS. Replace filter(s) when necessary, or clean the filter(s) if you have the reusable type.

Disposable filters should be replaced by similar, new filters of the same dimensions.

Reusable, permanent filters should be washed in a solution of cold water and mild detergent, then rinsed and thoroughly dried. THE FILTER MUST BE COMPLETELY DRY BEFORE BEING REINSTALLED. To avoid prolonged shutdown of your unit while a filter is drying, you should have an extra filter on hand. This allows you to rotate between the two with minimal downtime for your comfort system. Extra filters may be purchased from your dealer.

The filters(s) and filter rack for a packaged system are supplied and installed by the contractor or dealer. Typically, the filter(s) and rack are located in the return-air duct at the outdoor unit or behind the return-air grille(s). Have your dealer show you the location of your filter(s) and the procedures for removal and replacement.

If your system includes a high efficiency or electronic air cleaner, refer to air cleaner User’s Manual for proper filter cleaning or replacement.

B. Outdoor Coil

If grass clippings, leaves, shrubbery, and debris are kept away from the unit, minimal care should be sufficient to keep the system functioning properly. However, if the outdoor coil becomes dirty, use a vacuum cleaner or shop vac with soft brush attachment to clean the exterior surface. Vacuum coil surface using an up and down motion. Be careful not to bend or damage fins.

If dirt is deep in the coil, contact your dealer for service. Do not attempt this yourself.

C. Outdoor Coil—Sea Coast

If your unit is located near the ocean, special maintenance is required. Ocean mist/breeze carries salt, which is corrosive to most metals. Although your new unit is made out of galvanized metal and is protected by top-grade paint, you should take the precaution of additional maintenance which consists of periodically washing the unit. By washing all exposed surfaces and coil, you will be adding additional life to your unit. Please consult your installing contractor for proper intervals/procedures for your geographic area or service contact.

—3—

D. UNIT SUPPORT

Your packaged air conditioning unit should be maintained at a level position. If its support should shift or settle so that the unit is no longer level, you should correct the condition. Relevel it promptly to assure water drains out of the unit. If you notice that water or ice collects beneath the unit, arrange for it to be drained away from the unit.

BEFORE YOU REQUEST A "SERVICE CALL"

CHECK FOR THESE EASILY SOLVED PROBLEMS:

1.Check the indoor and outdoor disconnect switches. Verify that circuit breakers are ON or that fuses have not blown.

2.Check for sufficient airflow. Check the air filter(s) for any accumulations of dirt. Check for blocked return-air or supply-air registers. Be sure registers are open and unob- structed.

3.Check the settings on your indoor thermostat. If you desire cooling, make sure that the temperature control selector is set below room temperature and the SYSTEM or MODE control is set to COOL or AUTO. If you require warmth, make sure that the temperature control selector is set above room temperature and the SYSTEM or MODE control is set to HEAT or AUTO. The FAN control should be set to ON for continuous blower operation or AUTO if you wish blower to function only while your air conditioner is operating. If your comfort system still fails to operate, turn your system off and contact your servicing dealer for troubleshooting and repairs. Specify your apparent prob- lem, and state the model and serial number of your equipment. (You should have them recorded on the last page of this booklet.) With this information, your dealer may be able to offer helpful suggestions over the phone or save valuable time through knowledgeable preparation for the service call.

REGULAR DEALER MAINTENANCE

In addition to the routine maintenance that you perform, your home comfort system should be inspected regularly by a properly trained service technician. The inspection (preferably twice each year, but at least once every year) should include the following:

1.Routine inspection of air filter(s). Replacement or cleaning as required.

2.Inspection and cleaning of the blower wheel, housing, and motor as required.

3.Inspection and, if required, cleaning of coils.

4.A check of all electrical wiring and connections.

5.A check for secure physical connections of individual components within unit.

6.Operational check of the air conditioning system to deter- mine actual working condition. Necessary repair and/or adjustment should be performed at this time.

7.Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.

WARRANTIES

You have purchased a 564B series unit. Be sure to read the warranty at the back of this booklet carefully to determine the coverage for your unit.

FOR THE RECORD

Record the model, product, and serial numbers of your new equipment in the spaces provided. This information, along with the other ready-reference facts requested will be necessary should you ever require information or service.

Image 3
Contents Identifying Your System For Your SafetySafety Considerations Your Comfort SystemCooling Mode Performing Routine MaintenanceOperating Your AIR Conditioner For the Record Regular Dealer MaintenanceUnit Support WarrantiesUnit Data Installation Data

564B specifications

The Bryant 564B is an innovative heating and cooling solution designed to deliver reliable performance and efficiency in residential environments. This model stands out due to its advanced technology and user-friendly features, making it an ideal choice for homeowners seeking comfort, energy savings, and convenience.

One of the major highlights of the Bryant 564B is its efficient operation. This model boasts a two-stage cooling system that allows for better temperature control, ensuring that your home remains comfortable no matter the weather outside. Its variable-speed compressor adjusts cooling output based on the specific needs of your space, optimizing performance while minimizing energy consumption. This not only helps in reducing utility bills but also contributes positively to environmental sustainability.

In terms of design, the Bryant 564B is compact and sleek, making it suitable for various installation situations without taking up too much space. Additionally, it operates quietly, providing indoor comfort without disruptive noise, which is especially valuable during nighttime or in quiet neighborhoods.

The advanced controls integrated into the Bryant 564B further enhance its usability. It is compatible with Bryant’s smart thermostats, offering homeowners easy access to temperature settings, scheduling options, and energy monitoring through a mobile app. This level of control allows users to adjust their heating and cooling preferences remotely, promoting added convenience and efficiency.

A noteworthy feature of the Bryant 564B is its robust construction. Built to withstand harsh weather conditions, this model includes a weather-resistant cabinet designed to protect against rust and corrosion. The high-quality materials used in its construction ensure durability and long service life, making it a worthwhile investment for homeowners.

Additionally, the Bryant 564B fulfills stringent energy efficiency standards, which may qualify homeowners for rebates and incentives. It is recognized for its eco-friendly refrigerant, contributing to reduced environmental impact.

In summary, the Bryant 564B combines cutting-edge technology, efficient operation, and thoughtful design to provide a top-notch heating and cooling experience. With its impressive features and commitment to energy efficiency, it is an excellent choice for those looking to invest in a sustainable and effective climate control solution for their homes.