Vector VEC189 user manual Troubleshooting, Specifications

Page 6

VEC189_Manual_052005 5/24/05 6:57 PM Page 6

Battery Replacement

1.Release the battery compartment cover locks on either side of the unit and remove the cover.

2.Pull out the (two) batteries.

3.Disconnect the terminals and replace the batteries with the same type listed in the Specifications section of this manual.

4.Replace the battery compartment cover and engage the locks.

5.Turn one of the spotlight’s ON/OFF switches to the ON position to ensure proper operation of spotlight.

Safe Battery Disposal

Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of properly. Recycling is required, contact your local authority for information. Failure to comply with local, state and federal regulations can result in fines, or imprisonment. For more information on recycling this battery, call toll-free (877) 288-7722.

DC Plug Fuse Replacement

The fuse in the DC plug protects the charging circuit of the DC recharge adapter. If the AC recharger operates but the DC charging adapter does not, then the fuse may be opened.

To replace the fuse:

1.Unscrew the end cap of the DC plug (counterclockwise).

2.Remove spring center contact and fuse.

3.Check fuse with a continuity checker.

4.If blown, locate replacement fuse with same type and rating.

5.Replace the fuse, spring, contact and end cap.

6.Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.

7.Check for proper operation of DC charging adapter.

TROUBLESHOOTING

No Charge Indicator Light

If the Charge Indicator LED does not light when charging do the following:

A)Check for bad connection to the AC Recharge Port or 12 Volt DC Accessory Outlet

B)Check for bad connection to AC or DC adapters

C)Confirm there is a functioning AC or DC current

Operating Issues

1.When charging using the 120 volt AC method, the Spotlight will not operate. The Auxiliary Light will turn on when pressed while charging. Be sure all adapters are disconnected before Spotlight usage.

2.If the unit does not operate, the battery may be completely discharged. Charge the unit using the AC adapter following the directions in the manual.

3.If you suspect a bulb is blown, check the bulb filament. If filament is coiled and unbroken, the bulb is not blown. If filament is blown, replace bulb.

4.If you suspect the main fuse is blown, check it and, if necessary, replace with a new 20 amp spade fuse.

SPECIFICATIONS

Spotlight:

12 volt H4 dual-filament quartz halogen 100 watt bulb

Batteries:

Two maintenance-free, sealed lead acid,

 

6 volt, 6.0 Ah

AC Adapter:

500mA, 12 volt

Operating Voltage:

12 volts DC

6

7

Image 6
Contents 10,000,000 PowerSeries Important Safety Instructions Table of Contents Charging the Battery Main FuseOperating Instructions Care and Maintenance Troubleshooting Specifications