|
| FIGURE 5 |
4. | RECHARGING | DC Charger |
AC and DC recharge requires use of these supplied recharge adapters. Do not charge spotlight using
any other adapters (see figure 5).
AC Recharge
AC Charger
Make sure that the AC source is 110/120 volts, 60 Hz.
Warning: Use the supplied AC recharge adapter; do not substitute with any other. AC recharge requires the use of the supplied AC recharge adapter that supplies12 volts DC.
DURING AC RECHARGE/OR DC RECHARGE:
a)Never turn on while charging.
b)After recharge – disconnect cord and wait 5 minutes before use.
1.Lift the rubber plug from the recharge port (see Figure 3). It is there to keep out dust and moisture.
2.Connect the wall transformer charger to an AC source.
3.Plug the adapter’s barrel connecter into the recharge port located near the handle.
4.Recharge for 15 hours maximum.
5.After recharge, disconnect the barrel connector from the recharge port and store the adapter.
6.Replace the rubber plug in the recharge port.
DC Recharge
Make sure the DC source (jump starter, battery pack, vehicle accessory socket, etc) is 12 volt DC. The DC source should be able to supply at least 10 amps at 12 volt DC.
Warning: Use the supplied DC recharge adapter, do not substitute.
DC recharge requires the use of the supplied DC recharge adapter. Do not substitute with any other.
1.Lift the rubber plug from the recharge port. It is there to keep out dust and moisture.
2.Connect the DC recharge adapter’s DC plug to a 12 volt DC source.
3.Plug the adapter’s barrel connecter into the recharge port located near the handle.
4.Recharge for 3 hours maximum.
5.After recharge, disconnect the barrel connector from the recharge port and store the adapter.
6.Replace the rubber plug in the recharge port.
DC operation and recharge
You may operate the spotlight or area light directly from any 12 volt DC external power source supplying at least 10 amp capacity. The internal battery will be recharged while operating the spotlight or area light from external DC power source.
5.PERIODIC MAINTENANCE
All batteries lose charge over time, especially when they are warm. AC recharge is recommended every two months, when not in frequent use. Use the AC recharger and charge for the recom- mended time. If the unit gets dirty gently clean the outer surface of the spotlight unit with a soft cloth moistened with a mild solution of water and detergent. Periodically inspect the condition of recharge adapters, connectors, and wires. Replace any components that may have become worn or broken.
6.PARTS REPLACEMENT
Three parts are replaceable by users. The quartz halogen bulb and sealed lead acid battery are pro- prietary and are available through Vector Manufacturing. A substitute 12 volt H3 55 watt bulb may be used instead of a Vector bulb. These can also be purchased from popular automotive parts suppliers nationwide. The DC charging adapter fuse is replaceable. Contact Vector Manufacturing’s Technical Support Department for replacement parts and any additional information that you may need. They