PYLE Audio FCN200 instruction manual Clearing a Jammed Fastener

Page 8

899223 - 05-31-01.qxd 2/19/02 2:02 PM Page 8

WARNING: Never attempt to drive a fastener into material that is too hard. The fastener can ricochet causing personal injury.

WARNING: Disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, handing the tool to another person, making adjustments.

WARNING: Clean and inspect tool daily. Carefully check for proper operation of trigger mechanism. Do Not use the tool unless the trigger mechanism is functional. Do Not use if the tool is leaking air or needs any other repair.

CLEARING A JAMMED FASTENER

1.CAUTION: Disconnect tool from air supply.

2.Remove any remaining fasteners from the nailer.

A.Pull pusher back by pulling front knob (A) Fig. 21. This will retract the pusher face from the cleat strip.

B.Still using the front knob (A) Fig. 22, slide the pusher to the front bypassing the cleat strip.

C.Slide the remaining Fasteners out of the magazine. Fig. 23.

3.Use the 3/16” hex wrench to remove the three screws (A) Fig. 24 attaching the Driver Guide Plate and Gate (B) Fig. 24.

4.Slide out the Driver Guide Plate and Gate assembly. Fig. 25.

5.Pull the Driver Guide Plate and Gate assembly apart and remove the jammed Fastener. Fig. 26.

6.Replace the Driver Guide Plate and Gate with three screws.

Fig. 21

A

Fig. 22

A

Fig. 23

Fig. 24

A

B

8

Image 8
Contents Flooring Cleat Important Safety Instructions Read and Follow ALL Instructions899223 05-31-01.qxd 2/19/02 201 PM 899223 05-31-01.qxd 2/19/02 201 PM Power Source EMPLOYER’S Responsibilities Operating Instructions ForewordPreparing the Tool Using the Tool Clearing a Jammed Fastener Service and Repairs MaintenanceClean and Inspect Daily Troubleshooting Symptom Problems SolutionsAccessories PORTER-CABLE Limited ONE Year Warranty Canadian PORTER-CABLE Delta Service Centers