Bryant 113A warranty Guide Specifications General, Products

Page 37

GUIDE SPECIFICATIONS

GENERAL

System Description

Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.

Quality Assurance

Unit will be rated in accordance with the latest edition of ARI Standard 210.

Unit will be certified for capacity and efficiency, and listed in the latest ARI directory.

Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC.

Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval.

Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test.

Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 450 psig.

Unit constructed in ISO9001 approved facility.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only.

PRODUCTS

Equipment

Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R-410A), and special features required prior to field start-up.

Unit Cabinet

Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.

AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER 113A 1-1/2 TO 5 NOMINAL TONS

Fans

Condenser fan will be direct-drive propeller type, discharging air upward.

Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant.

Fan blades will be statically and dynamically balanced.

Condenser fan openings will be equipped with coated steel wire safety guards.

Compressor

Compressor will be hermetically sealed.

Compressor will be mounted on rubber vibration isolators.

Condenser Coil

Condenser coil will be air cooled.

Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed.

Refrigeration Components

Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of Puronr (R-410A) refrigerant, and compressor oil.

Unit will be equipped with high-pressure switch, low pressure switch and filter drier for Puron refrigerant.

Operating Characteristics

The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW.

Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at

_____ _F/_C.

The system will have a SEER of _____ Btuh/watt or greater at DOE conditions.

Electrical Requirements

Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to

_____ v.

Unit electrical power will be single point connection.

Control circuit will be 24v.

Special Features

Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

113A

37

Image 37
Contents Product Data Industry Leading Features / BenefitsModel Number Nomenclature Standard FeaturesSeer RNCCond FAN Physical DataAccessories Accessory ThermostatsLOW Ambient PSW KSALA0601AAA Motormaster Motor FAN Ball BearingAccessory Usage Guideline Sound Hood Charging Subcooling TXV-TYPE Expansion Device Electrical DataDimensions English Sizes 018-036 Dimensions English Size Dimensions SI Sizes 018-036 Dimensions SI Size Clearances Combination Ratings FF1ENP030 FY4ANF030 FX4CNF030FF1ENP036 Combination Ratings FE5ANB004+UI FE4ANB006+UIFV4BNB006 FY4ANF036Combination Ratings FY4ANF048 FY4ANB060 57500 11.50 13.50 3043587 113ANA060---F 113A*A018 Outdoor Section With CAP**1814A** Indoor Section Detailed Cooling CAPACITIES#700 113A*A024 Outdoor Section With CAP**2414A** Indoor Section800 900Detailed Cooling CAPACITIES# 875 113A*A030 Outdoor Section With CAP**3014A** Indoor Section1000 1125Detailed Cooling CAPACITIES# 113A*A036 Outdoor Section With CAP*3617A Indoor Section Cooling Indoor Capacity Power Furnace Model1050 1200Detailed Cooling CAPACITIES# 1225 113A*A042 Outdoor Section With 42 Indoor Section1400 1575Detailed Cooling CAPACITIES# 1600 113A*A048 Outdoor Section With CAP**4821A** Indoor Section1800 FE4ANB006Detailed Cooling CAPACITIES# 1750 113A*A060 Outdoor Section With CAR**6034A** Indoor Section2000 2250SDT TCG113A*A042---C Products Guide Specifications GeneralCatalog No. PDS113A---04

113A specifications

The Bryant 113A is a highly efficient air conditioning unit, specifically designed for residential use. A part of Bryant's esteemed line of heating and cooling solutions, the 113A stands out for its reliability, performance, and energy efficiency. It is built for homeowners seeking comfort and consistent indoor temperatures, even in extreme weather conditions.

One of the key features of the Bryant 113A is its impressive energy efficiency rating. This unit is equipped with a Seasonal Energy Efficiency Ratio (SEER) of up to 14.5, which allows consumers to save on energy bills while minimizing their environmental footprint. The 113A's energy-efficient compressor operates quietly and provides an effective cooling experience, making it suitable for both day and night use.

The Bryant 113A is designed with advanced technology that ensures optimal performance. It includes a single-stage compressor which effectively cools the indoor spaces without consuming excessive power. The unit employs a durable rust-resistant cabinet, ensuring durability and longevity even when exposed to the elements. These design elements not only enhance the system's durability but also make it visually appealing, seamlessly blending with various architectural styles.

Another significant characteristic of the Bryant 113A is its air filtration system. The unit is compatible with various air filters, which help to reduce dust, pollen, and other airborne allergens, promoting healthier indoor air quality. This feature is particularly beneficial for families with allergy sufferers, as it ensures a cleaner and more comfortable living environment.

The Bryant 113A also emphasizes easy installation and maintenance. Its compact design allows it to fit in tight spaces, while still providing robust cooling capabilities. Homeowners benefit from straightforward maintenance requirements, ensuring that the unit operates efficiently throughout its lifespan.

In conclusion, the Bryant 113A is a versatile air conditioning solution that combines efficiency, comfort, and innovative technology. With its respectable SEER rating, durable construction, advanced air filtration, and ease of maintenance, it remains a popular choice for homeowners looking to enhance their indoor climate without compromising on energy efficiency. Embracing the Bryant 113A means investing in superior comfort, reliability, and long-term savings.