SECTION 2: CIRCUIT
REQUIREMENTS
220V Operation
Serious personal injury could occur if you connect the machine to the power source before you have com- pleted the set up process. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The 3 HP motor on the Model G0471 will draw the following amps:
G0471 Motor Draw | 18 Amps |
Circuit Requirements
Only connect your machine to a cir- cuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same cir- cuit. If you are unsure, consult a qualified electrician.
Minimum Circuit Requirement ..... 20 Amp
Plug/Receptacle Type
Plug Type ............. NEMA |
Figure 1. Typical NEMA 6-20 plug and
receptacle.
Model G0471 3 HP Air Compressor |