Bard WH Series manual Heat Pump Wall-Mount Model Nomenclature, Ventilation Options

Page 12

Heat Pump Wall-Mount Model Nomenclature

 

 

 

 

WH

36

1

-

A

10

 

 

X

X

X

X

 

MODEL NUMBER l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

KW ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

- 1½ Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTS & PHASE

 

 

 

 

 

 

 

 

 

24

- 2 Ton

 

REVISION l

 

 

 

 

 

 

 

 

 

 

COLOR OPTIONS

 

 

 

 

 

 

 

A - 230/208/60/1

 

 

 

 

30

- 2½ Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X - Beige (Standard)

 

 

 

 

 

 

 

 

 

 

 

B - 230/208/60/3

 

 

 

 

36

- 3 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - White

 

 

 

 

 

 

 

 

 

 

 

 

 

C - 460/60/3

 

 

 

 

 

 

42

- 3½ Ton

 

SPECIALTY PRODUCTS 2

 

 

 

 

 

2

- Mesa Tan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

- 4 Ton

 

(Non-Standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

- Buckeye Gray

60

- 5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

- Desert Brown

 

 

 

 

 

 

 

VENTILATION OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

- Dark Bronze

 

 

 

 

 

 

 

 

 

(See Table Below)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XB

CONTROL MODULES

(See Chart Below)

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

FILTER OPTIONS

X - 1 inch Throwaway (Standard)

W - 1 inch Washable

P - 2 inch Pleated

1 For 0KW and circuit breakers (230/208 volt) or toggle disconnects (460 volt) applications, insert 0Z in the KW field of the model number. 2 Insert “D” for dehumidification with hot gas reheat. Reference Form F1743 for complete details.

OUTLET OPTIONS X - Front (Standard) T - Top (on WH30 and

WH36 Models)

Ventilation Options

MODELS

WH184, WH242

WH301, WH361

WH421, WH483, WH602

Description

Factory Installed

Field Installed

Factory Installed

Field Installed

Factory Installed

Field Installed

Code No.

Part No.

Code No.

Part No.

Code No.

Part No.

 

Barometric Fresh Air Damper - Standard

X

BFAD-2

X

BFAD-3

X

BFAD-5

 

 

 

 

 

 

 

Blank-Off Plate

B

BOP-2

B

BOP-3

B

BOP-5

 

 

 

 

 

 

 

Motorized Fresh Air Damper

M

MFAD-2

M

MFAD-3

M

MFAD-5

 

 

 

 

 

 

 

Commercial Ventilator - Spring Return w/Exhaust

V

CRV-2

V

CRVS-3

V

CRVS-5

 

 

 

 

 

 

 

Commercial Ventilator - Power Return w/Exhaust

---

---

P

CRVP-3

P

CRVP-5

 

 

 

 

 

 

 

Economizer (Internal) - Fully Modulating

E

EIFM-2B

E

EIFM-3C

E

EIFM-5C

 

 

 

 

 

 

 

Energy Recovery Ventilator - 230 Volt

R

WERV-A2B

R

WERV-A3C 1

R

WERV-A5C 1

 

 

 

 

 

 

 

Energy Recovery Ventilator - 460 Volt

R

WERV-C2B

R

WERV-C3C 1

R

WERV-C5C 1

 

 

 

 

 

 

 

1 Intake and exhaust can be independently adjusted.

Heat Pump Control Modules

Factory Installed

Field Installed

 

Description

 

 

Code

Part

Low Pressure

Low Ambient Control

 

Start Kit ￿

Outdoor

Number

Number

 

Control 1

and Relay ￿

 

Thermostat ￿

 

 

 

 

B

CMH-3

￿

 

 

 

 

 

 

 

 

 

 

 

E

CMH-7

 

￿

 

 

 

 

 

 

 

 

 

 

O

CMH-9

￿

￿

 

 

 

 

 

 

 

 

 

 

Q

CMH-14

 

 

 

 

￿

 

 

 

 

 

 

 

R

- - -

￿

￿

 

 

￿

 

 

 

 

 

 

 

S

- - -

￿

￿

 

￿

 

 

 

 

 

 

 

 

T

- - -

￿

￿

 

￿

￿

 

 

 

 

 

 

 

P

CMC-15 ￿

 

 

 

￿

 

 

 

 

 

 

 

 

U

- - -

￿

 

 

 

￿

 

 

 

 

 

 

 

1The low pressure control is auto reset. It includes a lock-out feature and is resettable from the wall thermostat. All low pressure controls use a timed bypass circuit

to prevent nuisance tripping during low temperature start-up.

2The low ambient control includes an 8201-008 (fan relay) and permits cooling operation down to 0°F.

3For WH242-A, WH301-A, WH361-A and WH421-A models. The CMC-15 can be used with any control module combination. NOTE: The compressor anti-cycle relay is standard on all heat pump models.

4The outdoor thermostat is adjustable from 0°F to 50°F. It is suitable for use as a compressor cut-off thermostat.

BARD MANUFACTURING CO. BRYAN, OHIO 43506 www.bardhvac.com

Due to our continuous product improvement policy, all specifications subject to change without notice.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.

Form No.

S3210

February, 2006

Supersedes S3210-106

Form No.

S3210-206

Supersedes

S3210-106

Page

12 of 12

Image 12 Contents
Engineered Features Ventilation System PackagesSpecifications 1-1/2 through 3 Ton Specifications 3-1/2 through 5 TonCapacity and Efficiency Ratings Barometric Fresh AIR Damper Bfad Standard Commercial Room Ventilator Performance Data CRV-2 WH18 & WH24 Total and Ventilation AirflowS3210-206 S3210-106 5 Performance and Application Data- WERV-*2B VLT VLS VLL HRT HRS HRLHRL VLT VLS VLL HRT HRS Ventilation RatePerformance and Application Data- WERV-*3C Performance and Application Data- WERV-*5C Minimum Clearances Required to Combustible Materials WH18, WH24, WH30, WH36 WH42, WH48, WH60Electrical Specifications C09 460-3 C15Heater Packages Field Installed Indoor Blower Performance CFM at 230 or 460 VoltsRated +10 Model 10o 15o 20o 25o 30o 35o 40o 45o 50o 55o 60o 65oBtuh WattsHeat Pump Wall-Mount Model Nomenclature Ventilation OptionsHeat Pump Control Modules