Troubleshooting
WARNING! Turn the on/off switch to the off position and unplug the tool from the power supply before performing trouble shooting procedures.
Trouble | Problem | Suggested remedy | |
|
|
| |
Band saw will not | Power cord not plugged in | Ensure that the cord is connected to the power supply | |
start |
|
| |
Power fault, fuse or circuit breaker | Check the power supply | ||
| |||
| tripped |
| |
|
|
| |
| Cord damaged | Use authorised service centre to repair or replace | |
|
|
| |
| Burned out switch | Use authorised service centre to repair or replace | |
|
|
| |
| Faulty motor | Use authorised service centre to repair or replace the | |
|
| motor | |
|
|
| |
Blade does not | Extension cord too long or undersized | Use extension cord heavy enough to carry the current | |
reach full speed |
|
| |
Tool is overheating | Turn off the tool and let it cool down to room | ||
| |||
|
| temperature. Inspect and clean the ventilation slots | |
|
|
| |
Blade not running | Loose blade | Check to see that the blade is tightened on the wheels, | |
straight |
| adjust the blade tension if necessary | |
|
|
| |
| Blade tracking not adjusted | Ensure that the blade is centred on the wheels by | |
|
| adjusting the blade tracking | |
|
|
| |
| Thrust bearings and guide pins not | Adjust all thrust bearings and guide pins as | |
| adjusted | recommended | |
|
|
| |
Vibration or | Loose parts | Check to see that all screws are securely tightened | |
abnormal noise |
|
| |
Moving parts excessively worn | Use authorised service centre to repair or replace | ||
| |||
|
|
|
16