Grizzly G3811, G1852, G1861 Jamming, Aligning Nosepiece, To repair a jam, To align the nosepiece

Page 11

Jamming

To repair a jam:

1.Remove any fasteners remaining in the gun.

2.Partially unscrew the cap screws that hold the nosepiece cover in place. Slide the nose- piece cover down and pull it off. Figure 5. (G1861: Remove the safety tip before removing the nosepiece cover.)

Jammed Brad

Nosepiece

Cap Screw

Nosepiece Cover

4.Remove any fasteners lodged in the nailer nose.

5.Re-attach the nosepiece cover. Make sure it lines up properly. G1861: Attach the safety tip.

6.Load fasteners and connect the nailer to the air supply.

7.Make sure the safety tip is functioning cor- rectly and that it slides freely. Test fire into a sample piece.

If jamming persists, make sure you are using fas- teners within the size range of this nailer. If jam- ming is due to worn or broken parts, repair or replace them before placing the nailer back into service.

Aligning Nosepiece

The nosepiece may become misaligned if the nailer has been dropped or otherwise mishan- dled. Misfiring and/or jamming will result if the nosepiece is misaligned – but correcting the problem is simple.

To align the nosepiece:

1.Remove the nosepiece cover.

2.Remove fasteners and visually inspect to see if the nail slot in the nosepiece is aligned with the nail slot in the magazine. If it is hard to tell, put a nail in and see if it slides through both slots easily.

3.If the nosepiece is misaligned, loosen the cap screws that secure it to the magazine and shift it until it lines up.

4.Re-assemble.

5.Do not put any fasteners into the magazine. Connect the air hose.Check for any leaking air. You will hear it hissing or feel it rushing through the spaces.

6.If everything sounds normal, press the safe- ty nose down on a piece of wood and pull the trigger a couple of times. Air should be exhausted normally each time.

DO NOT attempt to repair or service this gun without ensuring that all nails or sta- ples have been removed and that the gun is disconnected from its air source. Use extreme care when testing after freeing jams or after re-loading. Always wear approved safety glasses or goggles and quality hearing protection when operating pneumatic guns or other woodworking tools and machinery. Failure to do so could result in serious personal injury.

 

 

 

 

 

 

 

 

-10-

 

 

G1847 / G1852 / G 1861 / G3811 Air Nailers/Staplers

 

Image 11
Contents Model G1847 / G1852 / G1861 / G3811 Nail Guns & StaplersTable Of Contents Safety Instructions For Power Tools SafetySafety Instructions for Nail Guns General Information Operations Unpacking Connecting To AirTo load the nailer Loading Brads To load the stapler Loading StaplesTo ensure that the best quality air enters your nailer Test Fire Air QualityInspect and maintain the following items daily MaintenanceGeneral Cleaning & Oiling To align the nosepiece JammingAligning Nosepiece To repair a jamTo remove the driver Driver ReplacementTo re-assemble the nailer RingsClosure G1847 PSB15M G1852 PSB23M G1861 Gasket SET G3811 Parts Diagram Driver Guide Operating Air Pressure 65 to 90 P.S.I Fastener Length Nailer WeightParts and Accessories Troubleshooting Guide Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC