4. Insert nails into nail channel through rear of nail chamber (see Figure 4). Make sure nail points are towards bottom of tool.

Note: We recommend that you only use Powerfast brad nails in this tool. Wrong brad nails can cause jamming.

5. Replace nail pusher into nail chamber. Do this by inserting

flat metal end of nail pusher into

nail channel (see Figure 5). Nail Channel Fully push nail pusher into nail

chamber. Push hook end of nail pusher up and latch it to nail chamber.

Brad Nails

Figure 4

Figure 5

Operating Tool

Nail Channel

 

!WARNING

Keep trigger lock in the OFF position and finger off trigger until ready to drive nail.

!WARNING

Keep all body parts away from nail exit opening on tool.

1.Make sure trigger lock is in the OFF position.

2.Plug tool into a 115 Volt/60 Hertz outlet.

3.Grip tool firmly and hold against work surface. Use enough pressure to depress

safety lock. The safety lock is located on nail exit of tool (see Figure 6). IMPORTANT: The safety lock must be depressed for this tool to operate. This tool will not fire unless this is done.

Safety Lock

Figure 6