RIDGID R2720 manual Double Insulation, Electrical Connection, Extension Cords

Page 7

ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power tools, which eliminates the need for the usual three-wire grounded power cord. All exposed metal parts are isolated from the internal metal motor components with protect- ing insulation. Double insulated tools do not need to be grounded.

WARNING:

The double insulated system is intended to protect the user from shock resulting from a break in the tool’s internal wiring. Observe all normal safety precautions to avoid electrical shock.

NOTE: Servicing of a tool with double insulation requires extreme care and knowledge of the system and should be performed only by a qualified service technician. For service, we suggest you return the tool to your nearest authorized service center for repair. Always use original factory replace- ment parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. It should be connected to a power supply that is 120 volts, 60 Hz, AC only (normal household current). Do not operate this tool on direct current (DC). A substantial voltage drop will cause a loss of power and the motor will overheat. If your tool does not operate when plugged into an outlet, double-check the power supply.

EXTENSION CORDS

When using a power tool at a considerable distance from a power source, be sure to use an extension cord that has the capacity to handle the current the tool will draw. An undersized cord will cause a drop in line voltage, resulting in overheating and loss of power. Use the chart to determine the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter’s Laboratories (UL) should be used.

When working outdoors with a tool, use an extension cord that is designed for outside use. This type of cord is designated with “WA” on the cord’s jacket.

Before using any extension cord, inspect it for loose or exposed wires and cut or worn insulation.

**Ampere rating (on tool data plate)

0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0

Cord Length

 

Wire Size (A.W.G.)

 

 

 

 

 

 

 

 

 

25'

16

16

16

16

14

14

 

 

 

 

 

 

 

50'

16

16

16

14

14

12

 

 

 

 

 

 

 

100'

16

16

14

12

10

**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge

WARNING:

Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools or other obstructions while you are working with a power tool. Failure to do so can result in serious personal injury.

WARNING:

Check extension cords before each use. If damaged replace immediately. Never use tool with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury.

7

Image 7
Contents Double Insulated OPERATOR’S ManualIntroduction Table of ContentsPersonal Safety General Safety RulesWork Area Safety Electrical SafetyService Specific Safety RulesSymbol Name DESIGNATION/EXPLANATION SymbolsSymbol Signal Meaning ServiceElectrical Connection Cord Length Wire Size A.W.GElectrical Double InsulationHEX KEY Storage Tracking Knob Dust Collection BAG FeaturesProduct Specifications Adjustable Front Handle Drive RollerAssembly Selecting Sanding Belts Setting the Belt Sander SpeedOperation ApplicationsTurning ON/OFF the Sander Proper Hand PlacementSoft Start Feature Variable SpeedFront Handle HEX Bolt To INSTALL/CHANGE Sanding BeltTo Adjust Front Handle Belt Tension Release LeverTo lock-on the sander LOCK-ON Button Switch TriggerLocking on the Sander Operating the SanderTo Adjust Sanding Belt Tracking To empty dust bag To install/remove dust bagDust BAG Turn to Secure Dust BAG GrooveBrush Assembly Brush CAP MaintenanceBrush Replacement General MaintenanceSee Figures 13 Timing Belt ReplacementPage HOW to Obtain Service What is not Covered WarrantyDAY Satisfaction Guarantee Policy What is Covered Under the 3 Year Limited Service WarrantyModel No R2720 Serial No Customer Service Information