RIDGID OL50145MW manual Draining the TANKs, Quick-Connect, Coupler, Off

Page 13

OPERATION

n Attach 1/4 in. NPT male connector fitting to accessory or

1/4 in. QUICK

tool you intend to use.

n Insert the other end of the male connector to the quick

coupler on the open end of hose.

WARNING:

QUICK-CONNECT

air fitting

COUPLER

Always ensure the switch is in the OFF (O) position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet. Failure to do so could result in possible serious personal injury.

nConnect the power cord to the power supply.

nTurn the switch ON ( l ).

nPull out and rotate pressure regulator knob to desired line pressure. Turning the knob clockwise increases air pressure at the outlet; turning counterclockwise reduces air pressure at the outlet.

nFollowing all safety precautions in this manual and the manufacturer’s instructions in the air tool manual, you may now proceed to use your air-powered tool.

warning:

Air powered tools may require more air consumption than this air compressor is capable of providing. Check the tool manual to avoid damage to the tool or risk of personal injury.

nControl the amount of air flow with the pressure regulator knob. Turning the knob fully counterclockwise will completely stop the flow of air.

NOTE:  Always use the minimum amount of pressure necessary for your application. Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently.

nWhen finished, always drain the tank and unplug the unit. Never leave the unit plugged in and/or running unattended.

DRAINING THE TANKs

See Figure 11.

To help prevent tank corrosion and keep moisture out of the air used, the air tanks of the compressor should be drained daily.

NOTE: The air compressor has two separate tanks. Be sure to open drain valves for both and perform this operation for both tanks.

To drain:

nTurn the air compressor off.

nPull the ring on the pressure relief valve to release until pressure gauge reads less than 20 psi.

nRelease the ring.

 

 

 

 

 

 

 

 

Fig. 9

regulator

 

 

 

 

TO OPEN

tank

pressure gauge

 

 

 

 

pressure gauge

A

HULE-

MPRESSORCON

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

BOMBA

LUBRICACION

 

 

 

 

 

 

 

 

TM

 

 

 

 

 

 

 

 

 

DE

 

 

 

 

 

5

 

 

AC

 

 

 

 

 

100

 

 

IETE

 

 

 

 

 

50

150

 

 

 

 

 

 

 

0

200

 

 

 

 

 

 

 

0

230

 

 

 

 

 

 

 

bar

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

2

50

150

 

 

 

 

 

 

 

0

200

 

 

 

 

 

 

 

0

psi

 

 

 

 

 

 

 

 

bar 230

PRESSURE

 

 

 

 

 

 

Fig. 10

REGULATOR KNOB

 

 

 

 

OFF

ON

TANK drain

 

 

valveS (2)

ON

Fig. 11

OFF

nRotate drain valves counterclockwise to open.

nTilt tank to drain moisture from tank into a suitable container.

NOTE:  Condensate is a polluting material and should be disposed of in compliance with local regulations.

nIf drain valves are clogged, release all air pressure, remove and clean valves, then reinstall.

warning:

Unplug the air compressor and release all air from the tanks before servicing. Failure to depressurize tanks before attempting to remove valve may cause serious personal injury.

nRotate drain valves clockwise until tightly closed.

13

Image 13
Contents OIL Lubricated OPERATOR’S ManualIntroduction Table of ContentsElectrical Safety General Safety RulesService Work AreaSpecific Safety Rules Symbol Name DESIGNATION/EXPLANATION SymbolsSymbol Signal Meaning Electrical Speed and WiringExtension Cords Electrical ConnectionGlossary of Terms Product Specifications FeaturesDrain Valve Regulator Pressure GaugeInstalling the Handles AssemblyUnpacking Packing ListInstalling the SEMI-PNEUMATIC Tire Installing the dipstickChecking the oil Operation Using the air compressorApplications Attaching a hoseQUICK-CONNECT Draining the TANKsCoupler OFFReSET Button Checking the Safety ValveSafety Valve To Release AIR Ring Reset ButtonGeneral Maintenance MaintenanceLubrication Replacing the AIR FilterDipstick Changing the OILOil fill hole Drain plugProblem Cause Solution TroubleshootingWarranty Page Model No OL50145MW Serial No Customer Service Information

OL50145MW specifications

The RIDGID OL50145MW is a versatile and efficient multi-wattage LED work light designed to provide high-quality illumination for various applications. Ideal for both professional contractors and DIY enthusiasts, this work light combines advanced technology with exceptional durability, making it a reliable choice for any job site or workspace.

One of the standout features of the OL50145MW is its adjustable brightness settings. With multiple wattage options, users can customize the light output according to their specific needs. This flexibility allows for optimal lighting in different environments, whether you require a dim light for close-up tasks or a brighter setting for expansive areas. The LED technology used in this work light provides bright, clear illumination while consuming significantly less energy than traditional lighting solutions.

In addition to its adjustable brightness, the OL50145MW is built with a rugged, durable design that ensures it can withstand harsh working conditions. It is IP54 rated for water and dust resistance, making it suitable for outdoor use and challenging indoor environments. The body is constructed from impact-resistant materials, providing protection against drops and bumps, which enhances its longevity.

Another notable characteristic of the RIDGID OL50145MW is its portability. The light features a lightweight design and a convenient carrying handle, allowing users to easily transport it from one location to another. Moreover, it can be easily positioned due to its adjustable stand, providing versatile mounting options according to the task at hand.

For added convenience, the OL50145MW features an integrated hook that allows it to be hung in various locations, maximizing workspace lighting without requiring additional equipment. This is particularly advantageous for hands-free use when working in tight or elevated spaces.

Overall, the RIDGID OL50145MW stands as an exemplary solution for those seeking a reliable, high-performance work light. Its combination of advanced LED technology, customizable brightness settings, durable construction, and portability makes it a valuable tool for a wide range of applications. Whether you are on a construction site, working on home improvement projects, or need reliable lighting for automotive tasks, the OL50145MW is designed to meet the challenges of any job. With RIDGID’s commitment to quality and innovation, this work light proves itself to be an essential addition to any toolkit.