BEA 10MATRIX warranty Programming

Page 3

7 Programming

I.THE 3 CONFIGURATIONS

A.Configuration A: Single Loop Detector (MATRIX-S)

B.Configuration B: Dual Loop Detector in Independent Mode with Dipswitch #10 OFF (MATRIX-D)

C.Configuration C: Dual Loop Detector in Combined Mode with Dipswitch #10 ON (MATRIX-D)

Dip Switch

Configuration A

Configuration B

Configuration C

 

Single loop

Dual loop in independent mode

Dual loop in combined mode

 

OFF

 

ON

OFF

ON

OFF

ON

DS#1

See next table

High (loop A)

Low (loop A)

High (loop A)

Low (loop A)

 

 

 

 

 

[High –30%]

 

[High –30%]

DS#2

 

 

 

High (loop B)

Low (loop B)

High (loop B)

Low (loop B)

 

 

 

 

 

[High –30%]

 

[High –30%]

DS#3

Active mode

 

Passive mode

Active mode

Passive mode

Active mode

Passive mode

DS#4

ASB OFF

 

ASB ON

ASB OFF

ASB ON

ASB OFF

ASB ON

DS#5

Relay A :

 

Relay A :

Relay A :

Relay A :

Not used

Not used

 

Presence on

 

Pulse on loop

Presence on loop A

Pulse on loop A

 

 

 

loop A

 

 

 

 

 

 

DS#6

Relay A :

 

Relay A :

Relay A :

Relay A :

Relay B :

Relay B:

 

Pulse on loop

 

Pulse on loop A

Pulse on loop A

Pulse on loop A

Non-Directional

Directional AB

 

A

 

exit

entry

Exit

mode

mode

 

entry

 

 

 

 

 

 

DS#7

Relay B :

 

Relay B :

Relay B :

Relay B :

Relay B :

Relay B :

 

Presence on

 

Pulse on loop A

Presence on loop B

Pulse on loop B

Pulse on loop B

Pulse on loop A

 

loop A

 

 

 

 

 

 

DS#8

Relay B :

 

Relay B :

Relay B :

Relay B :

Relay B :

Relay B :

 

Pulse on loop

 

Pulse on loop A

Pulse on loop B

Pulse on loop B

Pulse on loop entry

Pulse on loop exit

 

A

 

exit

entry

exit

 

 

 

entry

 

 

 

 

 

 

DS#9

100 ms

 

500 ms

100 ms

500 ms

100 ms

500 ms

DS#10

Not used

 

Not used

Independent

Combined mode

Independent

Combined mode

II. POTENTIOMETERS

A Potentiometer for Adjustment of the Maximum Duration of a Presence Detection: from 1 min to Infinity (See PRESENCE TIME)

A Potentiometer for Adjustment of the Linear Sensitivity (Δf) for the Loop A: from 0.005% to 0.5% (See SENSITIVITY)

A Potentiometer for Adjustment of the Linear Sensitivity (Δf) for the Loop B: from 0.005% to 0.5% (See SENSITIVITY)

PRESENCE TIME

1 min 10 min1 hr

MIN

2 hr

MAX

Infinity 20 hr 5 hr

SENSITIVITY

0.5% 0.44%0.34% MIN

0.25%

MAX

0.005% 0.1% 0.18%

III. RELAY CONFIGURATION (DIPSWITCH #3)

A 10 position dip switch is located on the front of the Matrix single detector. Dip switch 3, 5, 6, 7 and 8 configure the relay, while dip switch 9 controls the duration of the pulse when the Matrix is configured for pulse operation, (as opposed to presence). Configurations are as follows:

DIPSWITCH 3:

OFF= FAIL-SECURE MODE Relay is NOT energized when power is applied. Relay is energized upon detection only. In this mode, the NO circuit is open, and the NC circuit is closed. Thus, if a closed circuit is required upon detection, one must use the NO and COM terminals since they would close upon detection. When the Matrix is NOT powered, it is in the same state as it would be for non-detection.

ON = FAIL-SAFE MODE Relay is energized as soon as power is applied and de-energizes upon detection or power loss. In this mode, upon powering the detector, the NO circuit becomes closed, and the NC circuit becomes open. Thus, if a closed circuit is required upon detection, one must use the NC and COM terminals, since they would now be OPEN during non-detection, and would close upon detection. When the Matrix is NOT powered, it is in the same state as it would be for detection.

 

DETECTION STATUS

 

 

FAIL-SECURE MODE (Active Mode)

 

 

 

(Relay is not energized upon power-on)

 

 

 

 

 

DIPSWITCH 3 = OFF

 

NO DETECTION

 

The COM and NO terminals are OPEN.

 

COM and NC terminals are CLOSED.

 

 

 

 

The relay is de-energized.

 

DETECTION

 

 

The COM and NO terminals are CLOSED.

 

 

COM and NC terminals are OPEN.

 

Same

 

 

The relay is energized.

 

 

 

 

 

The COM and NO terminals are OPEN.

 

UPON POWER LOSS

 

 

COM and NC terminals are CLOSED

 

 

 

 

The relay is de-energized.

FAIL-SAFE MODE (Passive Mode)

(Relay becomes energized upon power-on)

DIPSWITCH 3 = ON

The COM and NO terminals are CLOSED. COM and NC terminals are OPEN.

The relay is energized.

The COM and NO terminals are OPEN. COM and NC terminals are CLOSED. The relay is de-energized.

The COM and NO terminals are OPEN. Same COM and NC terminals are CLOSED.

The relay is de-energized.

75.1046.04 EN 20080505

Page 3 of 5

Image 3
Contents Description SpecificationsPrecautions Terminology SpecificationLoop Installation Tips WiringFCC Compliance Programming Programming cont’d AdjustmentsDipswitch Learning Process Frequecy Adjustment for Loop a for Single Loop DetectorTroubleshooting Loop Frequency Error LED DisplayCompany Contact Page 10MATRIXD1224 AplicacionesEspecificaciones Precauciones de SeguridadConformidad con la FCC Consejos de Instalación del CircuitoCableado LAS 3 Configuraciones ProgramaciónII. Potenciómetros Detección Común Típicamente 0,90 M AjustesIV. Interruptores DIP Interruptors Proceso DE AprendizajeInformación de contacto de la empresa Solución de ProblemasError DE Frecuencia DEL Circuito Estado DEL LED Senal del LED