Emerson CF787ORB00, CF787AW00, CF787GES00, CF787BS00 Motor HUB BLADE/FLANGE Assembly Notched Area

Page 5

4.The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.

MOTOR HUB

BLADE/FLANGE

ASSEMBLY

MOTOR HUB

NOTCHED AREA

M6 x 14mm CAPTIVE PAN HEAD SCREW (2 per blade/flange assembly)

Figure 3

5.Remove and retain the three switch housing mounting screws (Figure 4) from the switch housing plate. Engage the connector of the switch housing assembly with the motor connector (Figure 4). The two connectors are keyed and color-coded and must be mated correctly (color-to- color) before they can be engaged. Make sure the connector latch closes properly.

SWITCH HOUSING

ASSEMBLY

SWITCH HOUSING

CONNECTOR

MOTOR CONNECTOR

SWITCH HOUSING

MOUNTING SCREW (3)

Figure 4

6.Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three M4 x 12mm flat head screws (supplied) (Figure 5).

! WARNING

To avoid possible fire or shock, do not pinch wires between the switch cup assembly and the switch cup plate.

SWITCH HOUSING

ASSEMBLY

 

M4 x 12mm FLAT HEAD

Figure 5

SCREW (3)

 

7.Carefully turn partially assembled fan upside down and place in strofoam form carton, in preparation for final installation.

8.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 6). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 9.

PIN

HANGER

BALL

DOWNROD

Figure 6

SETSCREW

 

 

9.Separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Remove the upper setscrew from the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 7). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed. Reinstall the upper setscrew in the motor coupling. Check that the lower setscrew is tightened securely (Figure 7).

5

U.L. Model No.: CF787

Image 5
Contents Carrera Grande Safety Instructions Unpacking Instructions Electrical Requirements How to Put Your Ceiling Fan TogetherMotor HUB BLADE/FLANGE Assembly Notched Area Ceiling Cover Downrod Coupling Cover How to Hang Your Ceiling Fan Two knurled knobs supplied. Figure How to Wire Your Ceiling FanAccessories Using Your Ceiling FanMaintenance Energy Efficient Use of Ceiling Fans Trouble ShootingKey Model No Description Repair Parts ListingLimited Warranty

CF787GES00, CF787AP00, CF787AW00, CF787ORB00, CF787GBZ00 specifications

The Emerson CF787 series ceiling fans, including models CF787BS00, CF787GBZ00, CF787ORB00, CF787AW00, and CF787AP00, are designed to enhance both functionality and aesthetic appeal in modern living spaces. Each model features a sleek and contemporary design, making it a perfect addition to any room, whether it’s a cozy living area, a stylish bedroom, or a spacious office.

One of the main features of the Emerson CF787 ceiling fans is their efficient motor technology. Equipped with a powerful and efficient DC motor, these fans provide superior airflow while consuming less energy compared to traditional AC motors. This not only ensures a comfortable environment year-round but also contributes to energy savings, making them an eco-friendly choice for households.

Each fan in the CF787 series offers a variety of speed settings, allowing users to customize their comfort level with ease. With multiple speed options available, users can choose the right setting for their immediate needs, whether they are cooling down on a hot summer day or circulating warm air during winter months. The quiet operation of these fans also means that they won’t disrupt conversations or peaceful evenings at home.

The design features of the CF787 series are equally impressive. Each model boasts a modern aesthetic with a clean and streamlined appearance, available in various finishes including brushed steel, gunmetal, oil-rubbed bronze, white, and antique pewter. The distinct color options enable homeowners to select a fan that complements their décor and personal style.

Another notable characteristic of the Emerson CF787 fans is their versatility in installation. They come compatible with a variety of ceiling heights and can be installed with either a standard or angled mount. Additionally, many of these fans come with the option for quick installation, making it easy for homeowners to set up their new ceiling fan without professional assistance.

Lighting is another functional aspect of the CF787 series, as several models include integrated LED lighting, providing both illumination and energy efficiency. The adjustable brightness levels and color temperature options further enhance the versatility, allowing users to tailor the lighting to suit their ambiance preferences.

In conclusion, the Emerson CF787BS00, CF787GBZ00, CF787ORB00, CF787AW00, and CF787AP00 ceiling fans are attractive and efficient solutions for modern living spaces. Their advanced motor technologies, customizable speed settings, stylish designs, and installation flexibility make them excellent choices for any home. With these ceiling fans, homeowners can enjoy enhanced comfort and aesthetic appeal, all while contributing to energy conservation efforts.