Sears 200.713201 owner manual Troubleshooting, Problem Possible Cause SOLUTION/REASON

Page 13

TROUBLESHOOTING

Performance problems often result from little things that you can fix yourself. Please read through this chart for a possible solution if a problem occurs.

PROBLEM

POSSIBLE CAUSE

SOLUTION/REASON

No ammeter reading.

Clamps not making good

Check for poor connection at battery. Make

 

connection.

sure clamps and posts are clean. Battery

 

 

may not accept an AUTOMATIC charge if

 

 

severely discharged. Use MANUAL setting,

 

 

see "Using Your Battery Charger" on page 6.

 

2-amp charge rate.

Ammeter needle will indicate little activity at

 

 

the 2-amp charge rate.

 

No AC power reaching

Check AC outlet and extension cords for

 

charger.

loose fitting plug.

 

 

Check for open fuse or circuit breaker

 

 

supplying AC outlet.

Circuit breaker in

Shorted battery clamps.

Separate the clamps. Circuit breaker cycles

charger cycles on

 

when current draw is too high.

and off with a

Shorted battery.

 

clicking sound in the

Check for worn cables and replace if

MANUAL setting.

 

needed.

 

Charger leads reversed

Have a Sears technician test the battery.

 

on battery.

 

 

 

Correct connections.

 

 

 

Ammeter reads less

Extension cord too long

Use shorter or heavier extension cord.

than selected charge

or gauge too small.

 

rate when charging.

 

 

 

Battery has weak cell or

Sulfated battery will eventually take a

 

sulfated plate.

normal charge if left connected. If the

 

 

battery will not take a charge, have it

 

 

tested by a Sears technician.

 

Battery is partially

Continue charging battery.

 

charged.

 

 

 

 

Charger makes a

Transformer laminations

Continue charging. Buzz is not abnormal.

loud buzz or hum.

vibrate (buzz).

 

 

 

 

Ammeter needle

Battery severely

Continue charging battery for another two

stays at the right

discharged.

hours. If problem continues, consult a

side of the meter.

 

qualified technician.

 

Battery size selector

Make sure size selection is in proper 12 or

 

switch in the wrong

24 volt position.

 

position

 

 

 

 

If the above solutions do not eliminate the problem...call toll-free from anywhere in the U.S.A. 1-800-SEARS-64(1-800-732-7764)

7 AM to 4:30 PM CST Monday through Friday

SAFETY

OPERATION

MAINTENANCE

TROUBLESHOOTING

PARTS

13

Image 13 Contents
Safety Operation Maintenance Troubleshooting Parts 20/15/10/2 AMP Fully Automatic Battery ChargerFull Three Year Warranty WarrantySafety Operation Important Safety InstructionsHelp US Help YOU Have plenty of fresh water and soap Remove all personal metal itemsAvoid touching your eyes while Cord Wrap Cleat Before Using Your Battery ChargerOperation Maintenance Preparing Your Battery to be ChargedUsing Your Battery Charger Selector Switches Your charger has four switchesBattery Voltage Battery TypeCharge Type Charge RateNegative Post is Normally the ONE That is Grounded LED IndicatorsFigure a Negative Grounded SystemFigure B Calculating Charge Time Battery Battery Rating Charge-Time Hours TypeCCA AMP 10 AMP 15 AMP 20 AMPCharge Time Needed if Amp-Hours is Known Maintenance and CareCharge Time Needed if Reserve Capacity is Known Problem Possible Cause SOLUTION/REASON Item Description Part Number Replacement Parts List ModelPage Part
Related manuals