Friedrich R410A specifications Specifications Indoor Unit, Cooling Capacity

Page 2

SPECIFICATIONS (INDOOR UNIT)

ELECTRICAL DATA

TYPE

 

 

 

 

 

COOLING & HEATING

 

 

 

 

 

 

 

 

 

 

MODEL NAME

 

 

MW09Y3FM

MW12Y3FM

 

MW18Y3FM

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

 

 

1 - 230 / (208) V 60Hz

 

 

 

 

 

 

 

COOLING CAPACITY

2.7 kW / 3.3 kW

3.5 kW / 4.0 kW

 

5.2 kW / 5.55 kW

( Rated / Max )

 

 

9,500 / 11,300 BTU/h

12,000 / 13,600 BTU/h

 

17,800 / 19,000 BTU/h

 

 

 

 

 

HEATING CAPACITY

3.2 kW / 3.8 kW

4.1 kW / 4.5 kW

 

6.0 kW / 6.7 kW

( Rated / Max )

 

 

11,000 / 13,000 BTU/h

14,000 / 15,400 BTU/h

 

20,500 / 23,000 BTU/h

 

 

 

 

 

MOISTURE REMOVAL

1.7 Pts/hr (0.8 L/hr)

2.0 Pts/hr (1.1 L/hr)

 

4.9 Pts/hr (2.3 L/hr)

 

 

 

 

 

AIR CIRCULATION-High

324 cfm (550 m3/hr)

377 cfm (640 m3/hr)

 

388 cfm (660 m3/hr)

 

 

 

 

 

 

 

 

 

 

Power source of specification : 230V

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCRIMINATION

 

 

 

MFD-34ROM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1,200 / 1,200

r.p.m.

1,380 / 1,380

r.p.m.

 

1,480 / 1,480

r.p.m.

 

 

 

 

 

 

 

 

 

 

FAN SPEED

 

Middle

1,070 / 1,070

r.p.m.

1,230 / 1,230

r.p.m.

 

1,380 / 1,380

r.p.m.

 

 

 

 

 

 

 

 

 

 

 

( Cool / Heat )

 

Low

900 / 970

r.p.m.

1,050 / 1,110

r.p.m.

 

1,200 / 1,200

r.p.m.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quiet

800 / 850

r.p.m.

900 / 960 r.p.m.

 

1,060 / 1,060

r.p.m.

 

 

 

 

 

 

 

 

 

 

 

 

NOISE LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

38 dB / 38 dB

43 dB / 43 dB

 

45 dB / 45 dB

 

 

 

 

 

 

 

NOISE LEVEL

 

Middle

34 dB / 34 dB

40 dB / 40 dB

 

43 dB / 43 dB

 

 

 

 

 

 

 

 

 

 

 

( Cool / Heat )

 

Low

28 dB / 30 dB

33 dB / 34 dB

 

39 dB / 39 dB

 

 

 

 

 

 

 

 

 

 

 

 

Quiet

25 dB / 26 dB

28 dB / 30 dB

 

34 dB / 34 dB

 

 

 

 

 

 

 

 

 

 

 

 

PIPING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM LENGTH

 

 

 

82 ft.

(25 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM HEIGHT

 

 

 

49 ft.

(15 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAMETER SIZE

 

Liquid

 

 

 

1/4 inch

(6.35 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

 

 

3/8 inch (9.52 mm)

 

 

 

1/2 inch (12.7 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEASUREMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

H x W x D

 

 

10-13/16 x 31-1/8 x 8-7/16

inch

 

 

 

 

(275 x 790 x 215 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEIGHT

Net / Gross

 

 

 

18 lbs. / 23 lbs.

 

 

 

 

 

 

(8.5 kg / 10.5 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2006.05.12

1

Image 2
Contents Contents Wall Mounted typeSpecifications Indoor Unit Cooling CapacitySpecifications Outdoor Unit CompressorSpecifications Combination Electrical Data 230Outline and Dimensions Outdoor Unit Refrigerant System Diagram Outdoor unitCircuit Diagram PCBModel MR36TQY3F Indoor PCB Circuit Diagram MW09Y3FM MW12Y3FM MW18Y3FM Indicator PCB Assembly Outdoor PCB Circuit Diagram Model MR36TQY3FController PCB Asemmbly Power Supply PCB Assembly Error Contents Outdoor Unit Leds Disassembly Illustration 236 39 37 40 27 61-2 Model MR36TQY3F 1110 2006.04.26 Model MR36TQY3F White Parts List Outdoor Unit Standard Accessories Use0604G3076
Related manuals
Manual 45 pages 45.67 Kb Manual 7 pages 15.54 Kb Manual 61 pages 11.89 Kb

R410A specifications

Friedrich R410A is a refrigerant blend that has become a cornerstone in the HVAC industry, particularly for air conditioning systems. This hydrofluorocarbon (HFC) is known for its efficiency and environmentally friendly properties, making it a popular alternative to older refrigerants like R22.

One of the main features of R410A is its exceptional thermal efficiency. It has a higher cooling capacity compared to R22, which allows for smaller and more efficient equipment. This efficiency translates to reduced energy consumption and lower operating costs for users. Additionally, the higher pressure capability of R410A enables the design of more compact systems, which is particularly beneficial for residential and commercial applications where space is often limited.

R410A is characterized by its zero ozone depletion potential (ODP), which is a significant advantage over its predecessors. This makes it a more environmentally responsible choice, aligning with global initiatives to phase out substances that harm the ozone layer. However, it is essential to note that while R410A does not deplete the ozone, it does have a global warming potential (GWP) of approximately 2,088, making it less favorable in terms of climate impact compared to natural refrigerants.

In terms of technology, R410A is typically utilized in systems that are designed specifically for this refrigerant. Equipment compatible with R410A often features advanced components that can handle the higher pressures required. Many modern air conditioning systems equipped with R410A also incorporate variable-speed compressors and advanced electronic controls, enhancing overall performance and comfort.

Additionally, R410A systems often come equipped with variable refrigerant flow (VRF) technology, which allows for precise temperature control in multiple zones of a building. This versatility makes R410A an ideal choice for both residential and commercial installations, providing optimal comfort throughout various spaces.

In summary, Friedrich R410A stands out due to its high energy efficiency, zero ozone depletion potential, and suitability for modern HVAC technologies. As the industry moves towards more sustainable practices, R410A serves as a reliable refrigerant that balances performance with environmental responsibility. It’s a significant choice for anyone looking to invest in efficient and eco-friendly heating and cooling solutions.