Dimplex LI 28TEL, LI 24 TEL, LI 20TEL manual Set-UP, Installation

Page 6

6.2

5 Set-UP

5.1General Information

The unit must be installed indoors on a level, smooth and hori- zontal surface. The entire base of the frame should lie directly on the floor to ensure a good soundproof seal. If this is not the case, additional sound insulation measures may be necessary. If the device is installed on top of a built-under buffer tank, a surface that fully supports the base is required. The heat pump must be installed so that maintenance work can be carried out without being hindered. This can be ensured by maintaining a clearance of 1 m in front and to the left and right of the heat pump.

 P

P

P

 P

Never install the device in rooms subject to high humidity. Con- densation can form on the heat pump and air circuit if the humid- ity exceeds 50% and the external temperature is below

O °C.

If the heat pump is installed on an upper storey, the load-bearing capacity of the ceiling should be checked. On account of the acoustics, measures for isolating possible vibrations should also be very carefully planned in advance as well. Installation on a wooden floor is not recommended.

5.2Condensed Water Pipe

Condensed water that forms during operation must be drained off frost-free. The heat pump must be mounted on a level plane to guarantee proper drainage. The condensed water pipe must have a minimum diameter of 50 mm and should be fed frost-free into a sewer. Condensate should not be discharged directly into clearing tanks and cesspits because the aggressive vapours could destroy the evaporator.

5.3Sound

To prevent solid-borne sound from being transmitted to the heat- ing system, we recommend connecting the heat pump to the heating system using a flexible hose.

Installed air ducts should be sound-isolated from the heat pump to prevent the transmission of solid-borne sound to the ducts.

6 Installation

6.1General Information

The following connections need to be established on the heat pump:

„Fresh and exhaust air

„Flow and return flow of the heating system

„Condensate outflow

„Power supply

6.2Air Connection

ATTENTION!

Do not restrict or block the area around the air intake or outlet.

ATTENTION!

Only operate the heat pump with the air ducts connected.

The glass fibre reinforced concrete air ducts offered as accesso- ries are moisture-resistant and diffusion-free.

The sealing collar is used to seal the air ducts on the heat pump. The air ducts are not screwed directly onto the heat pump. Only the rubber seal comes into direct contact with the heat pump when the system is installed correctly. This guarantees easy as- sembly and disassembly of the heat pump and also ensures that solid-borne sound is well insulated.

If another type of air duct is used, observe the external and inter- nal dimensions as specified in the figure. Also ensure that the vi- bration and duct insulation are adequate.

If flange-mounted air ducts are used, connecting stubs are se- cured on the air inlet and air outlet sides of the evaporator with 4 M8 x 16 hexagon bolts in the threaded holes provided. When doing this, ensure that both air duct stubs only touch the insula- tion. There should be no contact with the external sheeting.

English

www.dimplex.de

E-5

Image 6
Contents LI 20TEL LI 24TEL LI 28TEL Table of contents Legal Regulations Directives Please Read ImmediatelyImportant Information Energy-Efficient Use Heat PumpApplication Purpose of the Heat PumpScope of Delivery Operating PrincipleSwitch Box TransportHeat Pump Controller Installation Set-UPHeating System Connection Electrical ConnectionProcedure Start-UPPreparation Maintenance / Cleaning Faults / Trouble- ShootingDecommissioning/ Disposal Device Information Type and order code DesignLI 28TEL Maßbilder / Dimension Drawings / Schémas cotés Anhang / Appendix / AnnexesMaßbilder / Dimension Drawings / Schémas cotés Maßbild / Dimension Drawing / Schéma coté LI 20TELIII Diagramme / Diagrams / Diagrammes 7HPSpUDWXUHGHVRUWLHGHO HDXHQƒ&@Annexes +HLZDVVHUGXUFKVDW Stromlaufpläne / Circuit Diagrams / Schémas électriques Steuerung / Control / CommandeLast / Load / Charge Anschlussplan / Circuit Diagram / Schéma électrique Abkürzungen Anhang · Appendix · Annexes XII Bivalente Anlage / Bivalent system / Installation bivalente XiiiXIV Anhang · Appendix · Annexes

LI 28TEL, LI 24 TEL, LI 20TEL specifications

Dimplex is a renowned name in the electric heater market, and its LI series, comprising the LI 20TEL, LI 24TEL, and LI 28TEL models, exemplifies innovation in energy-efficient heating solutions. These wall-mounted convection heaters combine sleek design with advanced technologies to meet the diverse needs of modern living spaces.

The LI 20TEL is a compact unit, specifically designed for smaller rooms or spaces where efficiency is paramount. With a capacity of 2000W, it delivers rapid warmth while maintaining energy efficiency. Its built-in thermostat allows for precise temperature control, ensuring that the desired comfort level is consistently achieved. This model also features a silent operation, making it suitable for bedrooms or offices where noise levels should be kept to a minimum.

The LI 24TEL, the middle variant in the series, offers a power output of 2400W, which is optimal for medium-sized areas. This model comes equipped with advanced technology that enhances its energy efficiency, including a programmable timer and multiple heat settings. Homeowners can easily customize their heating schedules to suit their daily routines, further reducing energy costs. This model also includes safety features such as an overheat protection mechanism, ensuring peace of mind during use.

The LI 28TEL stands as the most powerful option in the lineup, with a robust 2800W output, making it ideal for larger rooms or open-plan spaces. This model not only provides rapid heating but also employs advanced convection technology to circulate warm air efficiently throughout the room. Its external casing is designed to remain cool to the touch, providing an added layer of safety for homes with children or pets. Additionally, the LI 28TEL includes Wi-Fi connectivity, allowing users to control the unit remotely via a smartphone app, making it a truly modern heating solution.

In summary, the Dimplex LI series - LI 20TEL, LI 24TEL, and LI 28TEL - represents an excellent blend of modern aesthetics and high-performance heating technology. Each model is equipped with features tailored to different space requirements, from compact efficiency to powerful output. With energy-saving options, programmable settings, and enhanced safety features, Dimplex continues to lead the way in providing high-quality electric heating solutions for today's energy-conscious consumers.