Philips P-5611-B manual 830, 841, Life Expectancy at 12 Hours per Start, Lumen Maintenance

Page 2

Philips Lighting Company

www.philips.com

Philips Lighting

200 Franklin Square Drive

 

281 Hillmount Road

P.O. Box 6800

 

Markham, Ontario

Somerset, NJ 08875-6800

 

Canada L6C 2S3

1-800-555-0050

 

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Updated 12/04

P-5611-B

 

ALTO® PL-HCompact Fluorescent Lamps

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

 

 

 

 

Max.

 

 

 

Product

 

 

 

Standard

Lamp

 

Approx.

 

Overall

Average

Color

Color

Number

Ordering

Nominal

Lamp

Package

Current

 

Initial

Design

Length

Rated

Temp.

Rendering

046677-

Code

Watts

Base

Qty.

(mA)

Volts

Lumens1

Lumens2

(In.)

Life (Hrs.)3

(Kelvin)

Index (CRI)

 

 

 

 

 

 

 

 

 

 

 

 

 

830

 

 

 

 

 

 

 

 

 

 

 

 

13368-6

PL-H 60W/830/4P

60

2G8-1

10

800

80

4000

3440

7 1164

20,000

3000K

82

13370-2

PL-H 85W/830/4P

85

2G8-1

10

800

110

6000

5160

8 2532

20,000

3000K

82

13372-8

PL-H 120W/830/4P

120

2G8-1

10

800

153

9000

7740

111316

20,000

3000K

82

841

 

 

 

 

 

 

 

 

 

 

 

 

13369-4

PL-H 60W/841/4P

60

2G8-1

10

800

80

4000

3440

7 1164

20,000

4100K

82

13371-0

PL-H 85W/841/4P

85

2G8-1

10

800

110

6000

5160

8 2532

20,000

4100K

82

13373-6

PL-H 120W/841/4P

120

2G8-1

10

800

153

9000

7740

111316

20,000

4100K

82

1)Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.

2)Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

3)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 12 operating hours. Life is 18,000 hours at 3 hours per start.

2.58" Max.

2.24" Max.

A

B

C

Maximum Lamp Dimensions

Type

A Max.

B Max.

C Max.

Cap/Base 2G8

 

 

 

60W

5.55"

6.57"

7.17"

85W

7.17"

8.19"

8.78"

120W

10.20"

11.22"

11.81"

 

 

 

 

 

 

 

3.00"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.31"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ballast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

End View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.89"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.31"

 

 

 

 

 

 

 

 

 

Ballast Side View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.79"

 

Advance Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System

Lumen

 

 

Ballast

 

 

 

 

 

 

For

Wattage

Output

 

 

Type

 

 

 

 

 

 

Lamp

(W)

(Lumens)

 

 

ICF-1H120-M4-LD

1x 60W PL-H

70

4000

 

 

 

 

 

2x 60W PL-H

137

8000

 

 

 

 

 

ICF1H120-M4-BS {

1x 85W PL-H

98

6000

 

 

 

 

 

1x120W PL-H

137

9000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.00"

Ballast Top View

Life Expectancy at 12 Hours per Start

%

100

 

 

in

80

 

Survivals

 

 

90

 

 

70

 

 

 

 

Typical Values:

 

 

605.000 hrs: 98%

10.000 hrs: 97%

5015.000 hrs: 88%

0

5000

10,000

15,000

20,000

Operating Hours

Lumen Output vs. Temperature—

Horizontal Amalgam Up or Down

Lumen Maintenance

%

100

In

 

Lumen

90

 

 

80

 

70

 

60

 

50

0

5000

10,000

15,000

20,000

 

 

 

 

Operating Hours

Lumen Output vs. Temperature—

Base Up or Down

Relative Luminous Flux (%)

105

100

95

90

85

80

75

70

65

60

55

50

Amalgam

Amalgam

Horizontal Amalgam Up

Horizontal

Amalgam

Middle

Horizontal

Amalgam

Under

 

105

 

 

100

 

(%)

95

 

Flux

90

Base Up

85

 

Luminous

 

80

Base Down

75

 

70

 

Relative

 

65

 

60

 

 

55

 

 

50

 

0

10

20

30

40

50

60

70

80

100

 

Ambient Temperature in ºC (in draught-free air)

 

-10

0

10

20

30

40

50

60

70

80

Ambient Temperature in ºC (in draught-free air)

Image 2
Contents Amalgam Technology Long Life and High Lumen MaintenanceHigh Lumen Output Application Versatility841 Lumen Maintenance830 Life Expectancy at 12 Hours per Start