Dimplex LA16ASR manual Installation, Mounting, General, Condensate Line

Page 6

INSTALLATION MOUNTING

5INSTALLATION

5.1 General

The unit should always be installed on a permanently level, smooth and horizontal floor. The entire base frame surface should thereby make close contact with the floor in order to ensure adequate sound insulation and to prevent water-carrying parts from cooling out. If this is not the case, additional insulation measures may become necessary. It must be possible to carry out servicing work without any problems. This is ensured if a clearance of 1.2 m to solid walls is maintained.

1,2 m

1,2 m

1,2 m

1,2 m

CAUTION! The intake and discharge openings must not be restricted nor obstructed.

5.2 Condensate Line

The condensation water that may collect during operation must be drained in a place protected from frost. The heat pump must be positioned horizontally so that proper discharge can be ensured. The condensation water pipe must have a minimum diameter of 50 mm and should be discharged to the sewer drain in a frost-proof location.

6MOUNTING

6.1 General

The following connections need to be established on the heat pump:

-supply/return flow of heating system

-supply/return flow of hot water circuit

-condensate drain

-control lead to the heat pump controller

-power supply

6.2 Heating and Hot Water Connection

The connections on the heating side of the heat pump are provided with 1"external thread. The hoses to be connected exit the unit through its bottom. When carrying out the connections, use a wrench to counterhold at the transitions.

Before completing the heat pump connections on the heating water side, the heating installation must be flushed in order to remove any impurities that may be present and to ensure trouble-free operation of the heat pump. On systems equipped with heating water flow shut-off devices such as radiator or thermostat valves, an overflow valve to be provided by the customer needs to be installed behind the heating pump in a heating system bypass. This guarantees a minimum heating water flow through the heat pump and prevents any malfunctions from occurring.

Once the installation on the heating side has been completed, the heating system must be filled, de- aerated and pressure-tested.

Frost Protection

As a precaution against frost, manual drain valves should be provided. If the heat pump is placed out of service or in the event of a power failure, the system has to be drained at three points (see figure) and blown out. In heat pump installations where a power failure cannot be readily detected (holiday house), the heating circuit must contain a suitable antifreeze product.

Heat pump

3

1

2

6

Image 6
Contents LA 16ASR Contents Read Immediately Legal Provisions and Guidelines Read ImmediatelyImportant Information Energy-Efficient Use of the Heat PumpApplication Purposepump of HeatScope of Delivery Principle of OperationTransport Control BoxHeat Pump Controller General InstallationMounting Condensate LineElectrical Connection Procedure During Heating SeasonCommissioning Preparatory StepsMaintenance Cleaning MaintenanceProcedure During Cooling Season Cleaning of Heating SidePlacing Out of Service in Summer Malfunctions / TroubleshootingCleaning of Air Side DecommissioningAppendix Dimension Drawing Equipment Data Heating Mode Cooling Mode Appendix 11.4 Wiring Diagrams Control1L3/PE LoadTerminal Diagram X5 /X6Crankcase heater, compressor Appendix 11.5 Hydraulic Block Diagram Hydraulic Block DiagramDeclaration of Conformity EC Declaration of ConformityPage Page

LA16ASR specifications

The Dimplex LA16ASR is an innovative heating solution designed to deliver both efficiency and comfort in a compact form factor. This model is particularly aimed at residential users seeking effective space heating without the bulk of traditional radiators.

One of the standout features of the LA16ASR is its advanced convective heating technology. This allows for quick warming of the living space, creating a cozy environment in no time. The convection process heats air around the unit, which then rises and circulates throughout the room, providing a consistent temperature without creating cold spots. This mechanism not only enhances comfort but also optimizes energy use.

Another key characteristic of the Dimplex LA16ASR is its integrated thermostat. The built-in thermostat allows users to set their desired temperature easily, ensuring that the heater operates efficiently by maintaining the preset level. This feature minimizes energy consumption, making the unit an eco-friendly choice while also reducing utility bills.

The design of the LA16ASR is sleek and modern, making it suitable for a variety of room decors. With a compact size, it can fit seamlessly into tight spaces without compromising performance. The heater is also lightweight, making it easy to move from one room to another as needed.

Safety is paramount in HVAC systems, and the LA16ASR does not disappoint. It is equipped with overheat protection, automatically switching off the unit if it reaches excessively high temperatures. This feature provides peace of mind, particularly in homes with children or pets.

In addition to its impressive heating capabilities, the Dimplex LA16ASR is designed for quiet operation. Unlike traditional heaters that can be noisy, the LA16ASR operates without the disruptive hum, allowing for a serene environment, ideal for both homes and offices.

Finally, the LA16ASR is energy efficient and environmentally friendly. Its design and technology work together to minimize energy waste while providing immediate heat, making it an excellent investment for those looking to cut down on energy costs without sacrificing comfort.

In summary, the Dimplex LA16ASR combines effective heating technology with a modern design, safety features, and energy efficiency, making it an outstanding choice for anyone in need of a reliable heating solution.