Carrier 50XT manual Accessory Dimensions, No TE a

Page 9

ACCESSORY DIMENSIONS

HVACunit base

Screw

Gasketing

(NO TE A)

inner flange*

*Gasketing

 

outer flange

 

 

Wood nailer*

Flashing field

 

supplied

Roof curb*

 

Insulation(field

Roofing material

supplied)

 

field supplied

 

 

Ductwork

Cant strip

field supplied

 

field supplied

 

 

Roof

*Provided with roof curb

 

Roof Curb for Small Cabinet

Note A: When unit mounting screw is used, retainer bracket must also be used.

HVAC unit

 

base

 

 

Gask eting

Screw

inner flange*

 

(NOTE A)

 

*Gasketing

 

outer flange

 

 

Wood nailer*

Flashing field

 

supplied

Roof curb*

 

Insulation(field

Roofing material

supplied)

 

field supplied

 

 

Ductwork

Cant strip

field supplied

field supplied

 

 

Roof

*Provided with roof curb

Roof Curb for Large Cabinet

Note A: When unit mounting screw is used, retainer bracket must also be used.

GBTyp.

F

Insulated deck pan

Return opening (B X C)

E

 

 

G

 

 

 

Supply opening

 

 

F

(B x C)

 

 

D

 

 

 

CTyp.

 

 

 

 

 

R/A

S/A

 

A

 

Gasket around

 

E

 

 

D

duct

 

 

 

Short

 

Insulated

Gasket around

Support

 

deck pan

outer edge

 

 

Long

 

 

 

Support

 

 

 

 

 

 

A05308

UNIT SIZE

CATALOG

A

 

B

 

C

 

D

 

 

E

 

F

 

G

NUMBER

IN. (MM)

 

IN. (MM)

IN. (MM)

IN. (MM)

 

IN. (MM)

 

IN. (MM)

 

IN. (MM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024-030

CPRFCURB006A00

8 (203)

 

11 (279)

16--

1/2 (419)

28

--3/4 (730)

30--

3/8 (771)

44

--5/16 (1126)

45--

15/16 (1167)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPRFCURB007A00

14 (356)

 

11 (279)

16

1/2 (419)

28

--3/4 (730)

30

3/8 (771)

44

--5/16 (1126)

45--

15/16 (1167)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-060

CPRFCURB008A00

8 (203)

16

--3/16 (411)

17--

3/8 (441)

40--

1/4 (1022)

41--

15/16 (1065)

44

--7/16 (1129)

46--

1/16 (1169)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPRFCURB009A00

14 (356)

16

--3/16 (411)

17

3/8 (441)

40--

1/4 (1022)

41

15/16 (1065)

44

--7/16 (1129)

46--

1/16 (1169)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Roof curb must be set up for unit being installed.

2.Seal strip must be applied, as required, to unit being installed.

3.Roof curb is made of 16-gauge steel.

4.Attach ductwork to curb (flanges of duct rest on curb).

5.Insulated panels: 1-in. (25 mm) thick fiberglass 1 lb. density.

6.When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl.

9

Image 9
Contents Product Data FEATURES/BENEFITSTable of Contents ARI* Capacities Model Number NomenclatureUnit Size Physical DataFactory-installed options Options and AccessoriesManual Outside AIR Damper Filter Rack50XT024-030 Unit Dimensions 50XT036-060 Unit Dimensions No TE a Accessory DimensionsSelection Procedure 50XT Suggested RiggingGiven Cooling Extended Performance Table Performance DATA-STANDARD ECM Indoor Motor50XT024 High Cool 50XT024 Low Cool50XT024 High Con’t Heating Capacity 50XT024 High50XT024 Low Con’t Heating Capacity 50XT024 Low50XT030 Low Cool 50XT030 High CoolTotal Sens 875 100050XT030 High Con’t Heating Capacity 50XT030 High50XT030 Low Con’t Heating Capacity 50XT030 Low50XT036 Low Cool 50XT036 High Cool50XT036 High Con’t Heating Capacity 50XT036 High50XT036 Low Con’t Heating Capacity 50XT036 Low50XT042 Low Cool 50XT042 High Cool50XT042 High Con’t Heating Capacity 50XT042 High50XT042 Low Con’t Heating Capacity 50XT042 Low50XT048 Low Cool 50XT048 High Cool1600 96550XT048 High Con’t Heating Capacity 50XT048 High15.6 21.150XT048 Low Con’t Heating Capacity 50XT048 Low50XT060 Low Cool 50XT060 High Cool2000 175050XT060 High Con’t Heating Capacity 50XT060 High50XT060 Low Con’t Heating Capacity 50XT060 LowMultiplication Factors Performance DataWet coil air delivery low stage Typical Piping and Wiring Application Data PH-HZ Range FLA Nominal MCA Mocp MIN MAX RLA LRA Electrical DataTypical Wiring Schematic Sequence of Operation ControlsModel Number 50XT Part I General Guide SpecificationsSpecial Features Catalog No 50XT---04PD

50XT specifications

The Carrier 50XT series represents a significant advancement in commercial rooftop air conditioning systems, delivering robust performance and energy efficiency for a variety of applications. Designed primarily for light commercial buildings, these units are a preferred choice for their reliability and advanced features.

One of the standout features of the Carrier 50XT is its energy efficiency. The system boasts a high Seasonal Energy Efficiency Ratio (SEER), which translates to reduced operational costs and a lower environmental impact. This efficiency is further enhanced by the use of variable speed scroll compressors, which adjust their speed based on the cooling demand, ensuring optimal performance while consuming less energy.

The 50XT series is equipped with an advanced microprocessor control system that allows for precise management of the unit’s operations. This smart technology facilitates easy integration with building management systems, enabling real-time monitoring and control. Additionally, the control system provides diagnostic capabilities, making maintenance and troubleshooting more straightforward and efficient.

The unit also features an innovative air distribution system that enhances indoor air quality. With the inclusion of advanced filtration options, the Carrier 50XT effectively reduces airborne pollutants and allergens, contributing to a healthier indoor environment. The design ensures optimized airflow and temperature control, making it suitable for a wide range of commercial settings.

Durability is another hallmark of the Carrier 50XT, which is constructed with robust materials resists corrosion and ensures a long operational life. The units are designed to withstand harsh environmental conditions, making them a reliable choice for various climates.

Furthermore, the Carrier 50XT series supports various refrigerants, including R-410A, which is known for its lower environmental footprint. This adaptability not only meets current regulatory standards but also positions the units as forward-thinking solutions for the evolving landscape of HVAC technology.

In conclusion, the Carrier 50XT series combines cutting-edge technology, energy efficiency, and durability, making it an ideal choice for light commercial applications. With features designed to enhance performance and comfort, as well as environmentally responsible operation, the 50XT units stand out as a smart investment for any commercial building.