Harbor Freight Tools 94572 operating instructions Fan Direction and Pattern Adjustment

Page 10

IMPORTANT: The Spray Gun must be cleaned immediately after use. Improper cleaning is a common reason for the Spray Gun not to work.

Fan Direction and Pattern Adjustment

Fan Direction

To change the direction of the fan from horizontal to vertical, loosen the Lock Ring and turn the Air Cap (1A) 90 degrees. After the adjustment, tighten the Lock Ring by hand. See FIGURE 3 below.

Lock Ring

Horizontal Fan

FIGURE 3

Air Cap

Vertical Fan

 

 

Pattern Adjustment

Warning!! Never exceed the Maximum Inlet PSI of MAX PSI.

1.Adjust the air pressure during operation with the Trigger (23A) fully depressed and the Air Control Knob (25A) (see FIGURE 1 on page 6) fully open. If you need to reduce the air pressure for specific areas, use the Air Control Knob (25A) or adjust the air com- pressor.

2.To set the pattern size specific to the job, use the Pattern Control Knob (7A) (see FIGURE 1 on page 6). By turning it counterclockwise (all the way open), the pattern will flatten. Turn the Pattern Control Knob (7A) clockwise for a round pattern.

See FIGURE 4 below.

FIGURE 4

Flat/Open

Round/Closed

SKU 94572

For technical questions, please call 1-800-444-3353;

Page 10

Troubleshooting section at end of manual.

 

 

Image 10
Contents For technical questions and replacement parts, please call PC. Hvlp Spray GUN KITContents Read all instructions before using this tool SpecificationsSafety Warnings and Precautions Save This ManualSKU For technical questions, please call Troubleshooting section at end of manual Unpacking Air Connection Control Layout Preparation Comparison Conventional versus Hvlp Spray GunsGeneral tips for Preparation Pattern Adjustment Fan Direction and Pattern AdjustmentFan Direction Viscosity To test the viscosity of a materialTechniques Maintenance After each useAssembly Diagram And Parts List For 1.4mm Spray Gun Assembly Diagram And Parts List For 1.0mm Spray Gun Troubleshooting section at end of manualProblem Spray Pattern DiagnosisProblem Cause SolutionLimited 2 Year Warranty