Haier 237410 manual Preparing the Operator, II. Preparing the Site

Page 5

A CAUTION

This equipment is compatible with most water based materials. See the wetted parts in the Tech- nical Data section and your fluid and solvent manufacturer’s compatibility information.

Do not use catalyzed materials in heated applica- tions.

I.Preparing the Operator

All persons who operate the system should be trained in the safe, efficient operation of all system compo- nents as well as the proper handling of the chemical coating. At a minimum, all operators should thoroughly read the safety, installation, and operation sections of this manual and the component manuals.

II.Preparing the Site

1 . Use at least a 5 HP (3.7 Kw) air compressor for efficient operation.

K E Y

Components you must supply:

ABleed-type master air valve Required for pump; order part no. 11 O-223, l/4” nptQ

B

Air

filter.

 

 

Order part no. 11 O - l 46, l/4

npt(f)

C

Air

supply line

 

D

Grounded 5 gallon metal pail

--

E

Air line moisture trap

 

Components supplied with package:

1Husky 307 pump

2G700N air spray gun

3Fluid heater

6 a Pump air regulator

6 b Gun air regulator

1 0 Whip hose

1 3 Drain hose

4 2 l/4” female quick

. disconnect coupler

4 3 Pump ground wire

4 4 Fluid regulator

4 5 Fluid filter

4 8 Filter drain valve

5 4 a Gun fluid hoses

5 4 b Gun air hose

5 8 T i e s t r a p

Fig. 1

2 . Clear obstacles and debris that could cause an unsafe operating environment.

3 . Bring an air line from your compressed air supply to the pump location. Be sure the air is dry and filtered. Install a bleed-type master air valve upstream from the pump. When it is closed and the pump air regulator (6a) is opened, the bleed- type master air valve relieves all air pressure to the system components.

4 . Ventilate the spray booth.

To prevent hazardous concentrations of toxic and/ or flammable vapors, spray only in a properly venti- lated spray booth. Never operate the spray gun

~unless ventilation fans are operating.

Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.

/’

I-

4 308-448

Image 5
Contents Page Parts Change Notice Symbols Table of ContentsEquipment Misuse Hazard II. Preparing the Site Preparing the OperatorGrounding the System IV. Connecting the Hose Set and Gun to the System See FigIII. Unpacking the System VII. Using the Fluid Heater VI. Using the G700N Air Spray GunSystem Component Information VIII. Using the Air Regulators and NeedleIX. Using the 3-Way Valve Operation Pressure Relief ProcedureII. Flush the Pump Before First Use III. Priming the SystemMeasured with #2 Zahn cup IV. Setting Fiuid and Air PressureII. How to Flush When to FlushFlushing Production Spraying VI. Shutting Down the SystemFlushina Model 237410, Series a PartsParts16’ 3 0 8 4 4 308-448 Technical Data