Graco 312579K important safety instructions Setup, Ground the Gun, Flush Before Using Equipment

Page 6

Setup

Setup

• Check that your shop air provides adequate air flow. See Technical Data, page 20, for minimum cfm requirements.

Recommended 5/16 in. (7.9 mm) ID hose, optional 3/8 in. (10 mm) ID air hose.

Set shop air pressure regulator (not supplied) according to paint manu- facturer’s recommendation. See maximum compliant air pressure on air cap.

Make sure no air restrictions, such as low-volume cheater-valves, obstruct the air flow. If an air adjusting valve is desired, use a Graco adjustable air valve (234784).

1.Shut off the air supply.

2.Install a shutoff valve (not supplied) down- stream of the air regulator to shut off gun air.

3.Install an inline air filter (not supplied) to clean and dry the gun air supply.

4.Connect a clean, dry, filtered air supply to the air inlet fitting. See FIG. 1.

5.Connect the fluid supply to the fluid inlet fitting.

fluid inlet

air inlet

ti11306A

FIG. 1

Ground the Gun

Check your local electrical code for detailed grounding instructions.

Ground the gun through connection to a Graco-approved conductive air supply hose.

Flush Before Using Equipment

The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a compatible sol- vent before using the equipment. See Flush, page 9.

6

312579K

Image 6
Contents Important Safety Instructions AirPro Gravity Feed Airspray GunContents Gravity Feed with Plastic Cup ModelsGravity Feed without Cup Gravity Feed with 3M PPS CupFire and Explosion Hazard Hvlp Guns Gun SelectionConventional Guns Compliant GunsSetup Flush Before Using EquipmentGround the Gun Adjust Spray Pattern Apply Fluid Pressure Relief ProcedureOperation Volatile Organic Compounds VOC RegulationSee Compliant Cleaning Methods Daily Gun MaintenanceClean Gun and Cup General TasksClean Nozzle and Air Cap Compliant Cleaning MethodsDaily Gun Maintenance 312579K Right TroubleshootingCause Solution WrongCause Solution Follow Pressure Relief Procedure, DisassemblyFluid Inlet Fitting Replacement RepairReassembly Parts Description Qty Part No. Description QtyAccessories Part No. DescriptionRepair Kits Sound Data Technical DataAir Consumption Gravity Cup Size oz 0.68 liter cupTechnical Data 312579K Graco Standard Warranty Graco InformationGraco Headquarters Minneapolis