Graco 290/390, 390 Classic Model 24U105, 190 important safety instructions Setup

Page 13

Setup

1.Connect Graco airless hose to sprayer. Tighten securely.

ti22219a

2. Connect other end of hose to gun.

ti22217a

3. Tighten securely.

ti22218a

4. Remove tip guard.

ti2769a

5. Check inlet strainer for clogs and debris.

ti5301a

Setup

6.Fill throat packing nut with TSL to prevent premature packing wear. Do this each time you spray.

ti5735b

7. Turn power OFF.

ti5316a

/.

/&&

8.Plug power supply cord into a properly grounded electrical outlet.

ti2810a

9. Turn prime valve down.

ti22220a

10.Place siphon tube set in grounded metal pail par- tially filled with flushing fluid. See Grounding, page 11. Do steps 1- 6 of Startup, page 14, to flush out storage oil shipped in sprayer. Use water to flush water-based paint or mineral spirits to flush oil-based paint and storage oil.

ti5856a

Flush

332758A

13

Image 13
Contents Electric Airless Sprayers Important Safety InstructionsModels ContentsGrounding 110V 120V USSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Burn HazardPersonal Protective Equipment Toxic Fluid or Fumes HazardCalifornia Proposition G H Component Identification Hi-Boy ModelsComponent Identification Stand Models Component Identification Lo-Boy Models Pressure Relief Procedure Grounding Pails Setup Startup Test Spray Pattern Clearing Clogs Relieve Pressure, CleanupOFF Electric Airless Sprayers Technical Specifications332758A Graco Information Graco Standard Warranty