Carrier 40QA024-060 specifications Contents, Installation

Page 1

40QA024-060 Ceiling-Suspended Fan Coil Units

Installation, Start-Up and Service Instructions

CONTENTS

SAFETY CONSIDERATIONS

Page

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . .1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17

Step 1 — Complete Pre-Installation

Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

UNPACK UNIT

INSPECT SHIPMENT

BEFORE INSTALLATION

Step 2 — Select Location . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Step 3 — Mount Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

WOODEN STRUCTURE

NEWLY BUILT CONCRETE SLAB

METAL STRUCTURE

PREVIOUSLY BUILT CONCRETE SLAB

TO MOUNT UNIT

TO INSTALL THERMOSTAT

Step 4 — Connect Refrigerant Piping. . . . . . . . . . . . . . . .7 Step 5 — Connect Condensate Drain Line . . . . . . . . . . .8 Step 6 — Make Electrical Connections . . . . . . . . . . . . .10 Step 7 — Install Thermostat . . . . . . . . . . . . . . . . . . . . . . . .12

Step 8 — Make Connections Between

Indoor and Outdoor Units . . . . . . . . . . . . . . . . . . . . . . . .15

CHECK ACCURATOR METERING DEVICE

COOLING ONLY SYSTEMS

HEAT PUMP SYSTEMS

START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18,19

After Extended Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . .18

Seasonal Changeovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Adjusting Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Operating Mode Memory . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Automatic Operation (Auto.) Mode. . . . . . . . . . . . . . . . . .18

Operating Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

FAN OPERATION

COOLING MODE OPERATION

HEAT PUMP OPERATION

DEFROST (Heat Pump Only)

SYSTEM SAFETIES

SPECIAL OPERATION, HEATING

CLEANING AND MAINTENANCE . . . . . . . . . . . . . . . . 19,20

Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Air Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

REMOVE AIR FILTERS

CLEAN OR REPLACE FILTERS

Clean Indoor Unit Bottom Panel . . . . . . . . . . . . . . . . . . . .20

Clean Indoor Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Clean Outdoor Coil (Outdoor Unit). . . . . . . . . . . . . . . . . .20

Clean Condensate Drains . . . . . . . . . . . . . . . . . . . . . . . . . .20

• CLEAN OR REPLACE DRAIN PAN

SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Before Calling for Service . . . . . . . . . . . . . . . . . . . . . . . . . .20

• IF SYSTEM FAILS TO OPERATE

FRESH AIR INSTALLATION OPTION . . . . . . . . . . . . . . . .20

Ventilation-Air Accessory . . . . . . . . . . . . . . . . . . . . . . . . . .20

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . .CL1, CL-2

Installing and servicing air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install or service air-conditioning equipment.

Untrained personnel can perform basic maintenance, such as cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on air- conditioning equipment, observe precautions in literature and on tags and labels attached to unit.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly. Consult local building codes and National Electrical Code (NEC) for special installation requirements.

Before installing or servicing system, always turn off main power to system. There may be more than one dis- connect switch. Turn off accessory heater power if appli- cable. Electrical shock can cause personal injury.

INSTALLATION

Installation instructions for fan coil units (Fig. 1) are con- tained in this manual. Refer to this manual for proper installa- tion of the complete system. Note that the outdoor units are shipped with installation and service instructions for basic in- stallation of the outdoor section. Be sure to make the connec- tions in Cooling Only Systems and Heat Pump Systems sec- tions on page 15 of this literature so that the unit will operate properly.

Refer to Table 1 for proper system matches.

Fig. 1 — Ceiling-Suspended Fan Coil Unit

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

Catalog No. 02-40QA0007-SI

Printed in U.S.A.

Form 40QA-7SI

Pg 1

706 3-06 Replaces: 40QA-5SI

Tab

3d

2c

 

 

 

 

 

Image 1
Contents Installation ContentsApplication Range System MatchesSystem Type Indoor Section Number Outdoor Section Number CoolingPhysical Data, Under Ceiling Cooling Only Units Complete Pre-Installation ChecksUnit Size Physical Data, Under Ceiling Heat Pump UnitsUnit Weight lbSize Ft-inFan Coil Unit Clearances Installing Hex-Head Mounting Bolts Fan Coil Unit Piston and Charge Combinations Cooling Only Systems Connect Condensate Drain LinePiston and Charge Combinations Heat Pump Systems Piston and Charge Combinations Heat and Cool SystemsMounting Hanging Brackets Electrical Data Component Location Typical Ceiling-Suspended System Line Power Connections ASR ASMEquip GND TranThermostats AccuRater Bypass Type Metering Device Components Cooling System Wiring Diagram Heat Pump Wiring Diagram START-UP Adjusting AirflowCleaning and Maintenance Schedule Cleaning and MaintenanceAir Filters Fig Task Monthly Quarterly Yearly Indoor UnitService Clean Outdoor Coil Outdoor UnitBefore Calling for Service Save the cost of a service Fresh AIR Installation OptionProblem Cause Typical Solution TroubleshootingCall for Free Catalog Service TrainingII. PRE-START-UP START-UP Checklist Preliminary InformationIII. Piping IV. START-UP START-UP Checklist

40QA024-060 specifications

The Carrier 40QA024-060 represents a significant advancement in the field of air conditioning and heat pump systems, designed to provide efficient climate control for both residential and commercial applications. This package unit integrates cutting-edge technologies to enhance performance, reliability, and ease of use, making it an ideal choice for a variety of settings.

One of the standout features of the 40QA024-060 is its energy efficiency. The unit is equipped with a high-efficiency compressor that is designed to minimize power consumption while still delivering optimal cooling and heating performance. This translates into lower energy bills and a reduced environmental footprint, aligning with the growing demand for sustainability in HVAC systems.

Another important characteristic of the Carrier 40QA024-060 is its compact design. The unit is engineered for space-saving installations, making it suitable for locations where space is at a premium. Its durable construction ensures longevity and reliability in various weather conditions, providing peace of mind for users.

The 40QA024-060 utilizes advanced refrigerant technologies, including the use of R-410A refrigerant, which is known for its superior cooling capabilities and lower ozone depletion potential compared to older refrigerants. This aligns with modern environmental standards and contributes to the goal of eco-friendly operation.

In terms of operation, the unit features a microprocessor-based control system that allows for precise temperature management. Users can easily set their desired indoor climate settings, and the system will automatically adjust operational parameters to maintain those conditions efficiently.

Flexibility is also a key advantage of the Carrier 40QA024-060. The unit offers various configurations and can be integrated with existing ductwork, making it adaptable to different residential or commercial layouts. Additionally, the option for variable-speed blower technology enhances comfort by providing consistent airflow and reducing temperature fluctuations.

The Carrier 40QA024-060 is also designed with serviceability in mind. Access panels and maintenance features make it easy for technicians to perform routine inspections or repairs, reducing downtime and ensuring optimal performance over the unit's lifespan.

In conclusion, the Carrier 40QA024-060 combines energy efficiency, advanced technology, and robust design to meet the demands of climate control in diverse environments. Its features make it a reliable choice for both residential and commercial applications, contributing to enhanced comfort and operational efficiency.