Graco Inc Xs4 AA, 309295, 244572 Fire, Explosion, and Electric Shock Hazard, Skin Injection Hazard

Page 4

Warnings

Warnings

Warning Symbol

WARNING

Caution Symbol

CAUTION

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instruc- tions.

WARNING

Fire, Explosion, and Electric Shock Hazard

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Electrostatic equipment must be used only by trained, qualified personnel who understand the requirements of this manual.

Ground equipment, personnel, object being sprayed, and conductive objects in work area. See Grounding instructions.

Only use grounded Graco conductive air supply hoses.

Check gun and hose resistance and electrical grounding daily.

Interlock the gun air supply to prevent operation unless ventilating fans are on.

Use and clean equipment only in well ventilated area.

Use cleaning solvents with highest possible flash point when flushing or cleaning equipment.

Always turn the electrostatics off when flushing, cleaning or servicing equipment.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equip- ment until you identify and correct the problem.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plas- tic drop cloths (potential static arc).

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Keep work area free of debris, including solvent, rags and gasoline.

Keep a working fire extinguisher in the work area.

Skin Injection Hazard

Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but is a serious injury. Get immediate surgical treatment.

Do not point the gun at anyone or at any part of the body. Do not put your hand or fingers over the spray tip. Do not stop or deflect fluid leaks with your hand, body, glove, or rag.

Never spray without the tip guard in place.

Lock the trigger safety when you stop spraying.

Follow the Pressure Relief Procedure, page 24, when you stop spraying and before cleaning, checking, or repairing equipment.

Check the hoses and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.

Tighten all fluid connections before each use.

4

309295L

Image 4
Contents 309295L Important Safety InstructionsII 2 G EEx 0.24MJ Smart Model Table of Contents List of Models Fire, Explosion, and Electric Shock Hazard Skin Injection HazardToxic Fluid Hazard Equipment Misuse HazardIntroduction How the Electrostatic AA Spray Gun WorksStandard Gun Gun OverviewSmart Gun Installation Install the SystemVentilate the Spray Booth Flammable or Toxic Vapor HazardNon-Hazardous Area Typical Installation Key Hazardous AreaConnect the Air Line Connect the Exhaust TubeElectric Shock Hazard Supply HoseFilter the Fluid Connect the Fluid LineSelect a Spray Tip Grounding Earth ground. See Check Electrical GroundingCheck Electrical Grounding Check Gun GroundingCheck Fluid Resistivity Check Fluid ViscosityLow Voltage Adjustment Low Voltage Adjustment Smart Guns OnlyOperation Maintenance Flush the Spray GunTi1465a Electrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Barrel Resistance Test Barrel ResistanceSpray Pattern Troubleshooting TroubleshootingProblem Cause Solution Gun Operation Troubleshooting Electrical Troubleshooting Pressure Relief Procedure RepairPrepare the Gun for Service Tools NeededTip Guard, Air Cap, Spray Tip, or Seat Housing Replacement Tip Guard, Air Cap, and Spray Tip Replace- mentRepair Electrode Replacement Electrode ReplacementFluid Tube Replacement Fluid Filter RemovalFluid Needle Replacement Spring Cap and SpringsBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power Supply and Turbine AlternatorTurbine Alternator Removal and Replacement Atomizing Air Adjustment Valve Repair Atomizing Air Adjustment ValveAir Valve Repair Air ValveES ON/OFF Valve Repair ES ON/OFF ValveParts Part No 85 kV Electrostatic Gun, Series C itemsRef. No Alternator Ref. No Atomizing Air Adjustment ValveRef. No ES ON/OFF Valve Description Qty AIR CAPPlug Adjustment valve 20, and ES ON/OFF valve 53 RefAIR CAP Assembly SWITCH, ES HI/LO Air Line Accessories AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesSpray Tip Selection Chart Fan Width at Orifice SizeTechnical Data Category DataGraco Information Graco Standard WarrantyToll Free

244572, 309295, 309295L, 244573, Xs4 AA specifications

Graco Inc is a leading manufacturer in the field of fluid management and dispensing equipment. Among its notable products is the Graco Xs4 series, specifically the models AA, 244573, 309295L, 309295, and 244572. The Xs4 series is widely recognized for its innovation, reliability, and versatility in handling a wide range of applications.

One of the main features of the Graco Xs4 products is their robust and compact design. These units are engineered for durability, making them ideal for industrial environments where heavy usage is the norm. The construction utilizes high-quality materials that ensure longevity and resistance to wear and tear, thus keeping maintenance needs to a minimum.

The Xs4 series is equipped with advanced fluid delivery technologies, which enhance performance and efficiency. For instance, these models are designed to provide consistent and accurate fluid transfer, reducing waste and improving overall productivity. The precision of fluid flow helps in ensuring high-quality finishes, especially important in operations such as painting and coating.

Additionally, the Graco Xs4 is renowned for its user-friendly interface. With intuitive controls, operators can easily adjust settings, ensuring optimal performance for varied applications. The ease of use contributes to a shorter learning curve for new operators, making it an attractive choice for companies training new employees.

The Xs4 models incorporate smart technology for real-time monitoring and diagnostics. This feature not only aids in maintaining operational efficiency but also helps in proactive maintenance, thus minimizing downtime. The ability to track performance metrics allows users to make informed decisions regarding equipment usage and maintenance schedules.

Versatility is another hallmark of the Graco Xs4 series. These units can handle a wide range of fluids, including water-based materials, solvent-based products, and even viscous substances. This adaptability makes them suitable for various industries, from automotive to construction and beyond.

In conclusion, the Graco Inc Xs4 series models AA, 244573, 309295L, 309295, and 244572 stand out due to their durable construction, advanced fluid management technologies, and user-centric design. With a focus on efficiency and reliability, they represent some of the best options available for professionals seeking high-performance fluid transfer solutions. As industries continue to evolve, the Graco Xs4 series remains at the forefront of innovation, meeting the dynamic needs of users around the world.