English
XTR™ 5 and XTR™ 7 Airless Spray Gun
Instructions/Parts
See page 7 for model numbers.
Maximum Working Pressure:
XTR 5: 5000 psi (35 MPa, 345 bar)
XTR 7: 7250 psi (50 MPa, 500 bar)
For use with protective coating materials
ti5045a312145B
IMPORTANT SAFETY INSTRUCTIONS. Refer to
your sprayer instruction manual for pressure relief, priming, and spraying instructions. Keep these instructions.
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point sym- bol alerts you to a general warning and the hazard symbols refer to
Instructions
WARNING
SKIN INJECTION HAZARD
•Do not point gun at anyone or at any part of the body.
• Do not put your hand over the spray tip.
•Do not stop or deflect leaks with your hand, body, glove, or rag.
•Do not spray without tip guard and trigger guard installed.
•Engage trigger lock when not spraying.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause seri- ous injury.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
•Tighten all fluid connections before operating the equipment.
•Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
•Keep work area free of debris, including solvent, rags and gasoline.
•Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present.
•Ground all equipment in the work area. See Grounding instructions.
•Use only grounded hoses.
•Hold gun firmly to side of grounded pail when triggering into pail.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
•Keep a working fire extinguisher in the work area.
Graco Inc. P.O. Box 1441 Minneapolis, MN | II 2 G c T6 | |
Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001 | ||
| ||
|
|