Graco Inc 12006, 309739 Troubleshooting, Problem Cause Solution, Follow Pressure Relief Procedure

Page 6

Troubleshooting

Troubleshooting

Problem

Cause

Solution

 

 

 

 

 

 

Gun fails to dispense when trigger is

Material lodged in nozzle

Follow Pressure Relief Procedure,

actuated

 

page 5. Clear nozzle of blockage.

 

 

 

 

Material supply, hose, passages,

Check material supply settings,

 

clogged

hoses, etc. for proper material supply.

 

 

 

 

 

Verify integrity of trigger pin through

 

 

yoke. Repair or replace cartridge

 

 

assembly as necessary.

 

 

 

Gun fails to dispense when trigger is

Tension of trigger needs adjustment

Check spring tension adjustment at

engaged

 

rear of gun. Spring tension should be

 

 

adjusted to allow approximately 1/32

 

 

in. of free play on trigger.

 

 

 

 

 

Verify integrity of trigger pin through

 

 

yoke. Repair or replace cartridge

 

 

assembly as necessary.

 

 

 

 

Needle and seat adapter loose or

Check that seat adapter is tightened

 

worn

firmly and flush to gun body.

 

 

 

 

 

Needle and seat adapter worn.

 

 

Replace components as necessary.

 

 

 

Seal leakage

Packing adjustment nut not snug

Follow Pressure Relief Procedure,

 

 

page 5. Tighten packing adjustment

 

 

nut.

 

 

 

 

Worn seals and packings

Rebuild gun as necessary.

 

 

 

Material leaks from gun inlet swivel

Worn seals

Replace seals.

 

 

 

6

309739

Image 6
Contents Pistol Grip Flow Gun Contents ModelsElectric Shock Hazard Grounding and Electrical Requirements Installation Trigger Lock EngagedTroubleshooting Problem Cause SolutionFollow Pressure Relief Procedure Troubleshooting Cartridge Disassembly Procedure ServiceDisassembly ReassemblyModel Reassembly With trigger 20 depressed, remove collar Parts Part No. Description QtyNUT Nozzle Technical Data Graco Standard Warranty Graco Information