3. Technical Data |
|
Dimensions (L x H x W): | approx. 11 13/16” x 9 15/32” x 2 17/32” |
| (Approx. 300 x 240 x 65 mm) |
Total weight: | approx. 3 lbs. (1.4 Kg) |
Connection cable with mains plug: | 10 ft (3 m) long |
Operating voltage: | |
Power consumption | 500W |
Heating up time: | 10 minutes |
Operating temperature: | |
| |
Diameter of adhesive inlet: | 1 11/16” (43 mm) |
Extension cable: | max. 65ft (20 m) long |
Wire cross section: | at least 16 a.w.g. (1.5 mm2) |
Air Supply / Pneumatic | Minimum - 45 p.s.i. (3 bar) |
| Maximum - 100 p.s.i. (7 bar) |
Approximate Spray Pattern | Minimum | Maximum |
Ultra Wide Spray Pattern / 985216 | 1 ½” [38mm] | 6” [150mm] |
Wide Spray Nozzle Assembly / 985122 | 1 ¼” [32mm] | 5” [127mm] |
Narrow Spray Pattern Assembly / 985211 | ½” [13mm] | 1 ¼”[32mm] |
4. Installation
Before using the tool for the first time check it carefully for signs of external damage. If any transit damage is found DO NOT USE THE TOOL - return it to your supplier immediately.
Steps 1 – 5 should be followed before connection to the mains supply:
1.Insert the applicator stand into the grooves at the base of the handle. Stand applicator on a flat surface.
2.Connect the air supply hose to a clean, dry and regulated air supply using the
3. Pull piston back fully and rotate upwards.
4.Load two adhesive cartridges into the barrel of the tool and push fully forward.
5.Rotate the piston down and slide forward fully until it contacts the rear of the adhesive cartridge - it should engage about 5/16"
4
3 | 5 |
2 |
USERS AIR SUPPLY | 1 |
6.Connect tool to mains supply.
7.Red ‘Power On’ indicator light illuminates.