Harbor Freight Tools 3273 Extension Cords, Symbology, See Table a, 25’ 50’ 75’

Page 8

in the preceding illustration. (See

Outlets for 2-Prong Plug.)

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.

(See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required.

(See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged

extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

EXTENSION CORD

 

LENGTH

 

AMPERES

 

 

25’

50’

75’

100’

150’

(at full load)

 

 

 

 

 

 

 

 

 

 

 

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

* Based on limiting the line

TABLE A voltage drop to five volts at 150% of the rated amperes.

Symbology

Double Insulated

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

V~

Volts Alternating Current

A

Amperes

 

 

 

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

SKU 3273

For technical questions, please call 1-800-444-3353.

Page 8

Image 8
Contents For technical questions or replacement parts, please call Heavy-duty 1/2 VSR DrillContents General Power Tool Safety Save This ManualGfci reduces the risk of electric shock Drill and Impact Drill Safety Vibration Safety Outlets for 2-Prong Plug GroundingDouble Insulated Tools Tools With Two Prong Plugs Symbology Extension CordsSee Table a 25’ 50’ 75’SpecificationsAssembly Tool Set UpUnpacking Instructions for putting into useWork Piece and Work Area Set Up General Operating InstructionsMetal Drilling Wood DrillingAfter Use SKU For technical questions, please callMaintenance Servicing Cleaning, Maintenance, LubricationCarbon Brush Service Chuck 1 ReplacementTroubleshooting Problem Possible Causes Likely SolutionsRecord Product’s Serial Number Here Parts ListPart Description Assembly Diagram Limited 90 DAY Warranty