Delta 17-900 instruction manual Extension Cords

Page 9

240 VOLT OPERATION

Your drill press may be converted for 240 volt operation.

The conversion of your drill press for 240 volt operation must be done by qualified electrical personnel. Should you desire to have your drill press converted for 240 volt operation, take your drill press to your local Authorized Delta Service Center. You can call 800-223-7278 for the location of the nearest Authorized Service Center.

When converted for 240 volt operation, your drill press is intended for use on a circuit that has an outlet like the one illustrated in Fig. 15. After conversion for 240 volts, the drill press will have a grounding plug that looks like the plug illustrated in Fig. 15.

Make sure the drill press is connected to an outlet having the same configuration as the plug. No adapter is available or should be used when the drill press is converted for 240 volts. If the drill press must be reconnected for use on a different type of electrical circuit, the re-connection should be made by qualified service personnel; and after re-connection, the tool should comply with all local codes and ordinances.

GROUNDED OUTLET BOX

CURRENT CARRYING

PRONGS

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. 15

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the drill press. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Fig. 16, shows the correct gauge to use depending on cord length and voltage. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

 

 

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. 16

9

Image 9
Contents 16½ Floor Model Drill Press Always Wear EYE Protection Safety RulesAdditional Safety Rules For Drill Presses Unpacking and Cleaning Assembly Changing Spindle Speeds and Adjusting Belt Tension Permanent Mounting Fastening Drill Press Base to a Supporting SurfacePower Connections Connecting Tool to Power SourceMotor Specifications Grounding InstructionsExtension Cords Locking Switch in the OFF Position Table AdjustmentsStarting and Stopping Drill Press Spindle Speeds Drilling Holes To Depth Changing Spindle Speeds Adjusting Belt TensionOperations Adjusting Spindle Return SpringInstalling and Removing Drill Bits Boring in WoodDrilling Metal Page Accessories