OPERATION

LOADING THE TOOL WITH STAPLES

See Figures 5 and 6.

nRemove battery pack from the tool.

nHold tool upside down; squeeze latch and slide base open.

nPlace staples in channel, legs facing upward and close base.

nMake sure the latch is securely locked in place.

nReattach battery pack to tool.

LOADING THE TOOL WITH BRADS

See Figures 5 and 7.

nRemove battery pack from the tool.

nHold tool upside down; squeeze latch and slide base open.

nPlace brads in the center of the channel with "T" head sitting on the slot base. Close base while making sure brad strip stays upright in channel.

NOTE: There are two channels for the brads. Use the smaller channel for brads sized 3/4 in. to 1 in. Use the larger channel for brads sized 1-1/4 in. Refer to molding on the tool.

nMake sure that the latch is securely locked in place.

nReattach battery pack to tool.

LATCH

Fig. 5

STAPLES

Fig. 6

3/4 IN. TO 1 IN. 1-1/4 IN.

BRADS

Fig. 7

12

Image 12
Contents OPERATOR’S Manual Save this Manual for Future ReferenceTable of Contents IntroductionGeneral Safety Rules Electrical SafetyPersonal Safety Work AreaSpecific Safety Rules ServiceSafety Rules for Charger Symbols Symbol Name DESIGNATION/EXPLANATIONSymbol Signal Meaning Features Features AssemblyCharging the Battery Pack Charging a Cool Battery PackOperation ApplicationsCharging a HOT Battery Pack To Install Battery PackTo Remove Battery Pack Loading the Tool with Staples Loading the Tool with BradsSetting Depth Maintenance General MaintenanceBattery Pack Removal Preparation for Recycling BatteriesPage Service Model NO. and Serial no