Electrical Data (Subject to change without notice)

Lamp Watts (Nominal)

100

Lamp Operating Voltage (rms) (Nominal)2

102

Initial Lamp Voltage Range (rms)3

82–112

Lamp Operating Current (Amps) (rms) (Nominal). . . .

1.1

Lamp Current Crest Factor (Maximum)

1.8

Warm-up Time to 80% of Output

2 Minutes

Re-strike Time for Hot Lamp

4–8 Minutes

Ballast Type

ANSI M140/M90/E

Ballast Open Circuit Voltage (Minimum)

249 RMS Min.

Pulse Peak Volts

3300 Min., 4000 Max.

Pulse Width @ 90% Peak

2 Micro Second Minimum

Pulse Repetition Rate (Minimum)

2 per Half Cycle

Minimum Operating Temperature

-30º C

1)Measured at 100 hrs of life in vertical position.

2)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.

3)Measured with the lamp operating at rated watts.

Warnings, Cautions and Operating Instructions

“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada: SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.

WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY

DAMAGE, BURNS AND FIRE.

Certain lamps that will retain all the glass particles should inner arc-tube rupture occur are commercially available from Philips Lighting Company.

RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

This lamp contains an arc tube with a filling gas containing Kr-85 and is distrib- uted by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey 08875-6800.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.

Lamp Operating Instructions:

1)RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

2)Use only in an enclosed fixture capable of withstanding particles of glass having temperatures up to 1000º C.

3)Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.

4)Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B.For total supply load refer to ballast manufacturers electrical data.

5)Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.

6)If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.

7)Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

8)Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.

9)Lamps may require 10 to 20 minutes to re-light if there is a power interruption.

10)Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.

Image 2
Contents Ordering Information Physical CharacteristicsOperating Characteristics Photometric Operating Position82-112 100102 Minutes

281352 specifications

The Philips 281352 is an exceptional display that caters to both professional and casual users with its impressive features and modern technologies. This monitor is designed to enhance productivity and provide an immersive viewing experience with its high-quality image performance.

One of the standout features of the Philips 281352 is its 4K Ultra HD resolution, boasting a pixel count of 3840 x 2160. This level of detail ensures sharp and vibrant visuals, making it ideal for tasks that require precision, such as graphic design, video editing, and gaming. The monitor's large 28-inch screen size allows for ample workspace, granting users the ability to multitask efficiently with multiple windows open side by side.

In terms of color accuracy, the Philips 281352 utilizes an IPS panel, which provides wide viewing angles and consistent color reproduction. This technology ensures that colors remain true-to-life, regardless of the angle from which you view the screen. The monitor supports a wide color gamut, offering rich and dynamic visuals that are essential for creative professionals.

Another impressive aspect of the Philips 281352 is its ergonomic design. The monitor features height, tilt, and swivel adjustments, allowing users to customize their viewing angles for optimal comfort during extended use. This ergonomic flexibility promotes better posture and reduces strain, enhancing overall productivity and user experience.

Connectivity options are plentiful with the Philips 281352. It comes equipped with multiple USB ports, HDMI, and DisplayPort connections, making it compatible with a wide range of devices including computers, laptops, and gaming consoles. This versatility enables seamless integration into various setups, whether in a home office or a gaming rig.

Additionally, the Philips 281352 includes features such as flicker-free technology and low blue light modes, which contribute to a more comfortable viewing experience by minimizing eye strain during long hours of use. This is an essential characteristic for anyone who spends significant time in front of the screen.

In summary, the Philips 281352 is a highly versatile monitor that combines impressive 4K resolution, excellent color accuracy, ergonomic design, and extensive connectivity options. Whether for professional or personal use, this monitor stands out as a reliable choice, delivering quality performance and enhancing the overall computing experience.