Before each use

CAUTION: Serious injury or death may occur if electrical sparks from motor and pressure switch come in contact with flammable vapors, combustible dust, gases or other combustible materials. When using the air compressor for spray painting, place the air compressor as far away from the work area as possible. Use extra air hoses instead of extension cords.

CAUTION: In order to avoid damaging the air compressor, do not incline the air compressor transversely or longitudinally more than 10°.

Pre-Start Checklist

Check pressure-hose for damages and replace, if necessary.

Check all screwed connections for tightness and tighten, if necessary.

Check power-cable for damages and have it replaced by service-station, if

necessary.

ƒThe compressor must operate only in dry environment.

ƒPlace air compressor at least 12 inches away from obstacles that may prevent proper ventilation.

ƒPlace the power-cable in a way that it does not interfere your work and that it is not damaged.

ƒBefore connecting the compressor to the power supply, always check the switch is in position “OFF”. (see FIG. 1)

ƒProtect the power-cable against heat, oil or sharp edges.

ƒAlways switch off the compressor by using the main-switch and do not stop by unplugging.

ƒAfter having finished your job, switch the compressor off and disconnect from the power- supply

Start up (see FIG. 4 on page 12)

1.Check the switch is in the “OFF” Position.

2.Plug the power cord into the grounded outlet. (see FIG. 1)

FIG. 1

3.Switch the compressor “ON” (pull switch up) and wait; until the maximum tank pressure is reached at 115 psi. (The motor will stop automatically). The tank-pressure is indicated on the tank pressure gauge.

11

Image 12
Contents Gallon OIL Free AIR Compressor Table of Contents Important Safety Instructions PreventionIntended USE Additional safety guidelines for compressors Page Wire Sizes Extension Cord Length Gauge A.W.GGeneral Safety Rules Save ALL Instructions Work Area Electrical SafetyPersonal Safety Tool USE and CareService Technical Specifications List of Main PartsContents of Packaging InstallationOperation Start up see onPage Shutdown Maintenance After approx hours operating timeTrouble Shooting Problem Cause SolutionSolution. do not Over TightenDo not Drill Into Weld orOtherwise Modify AIR Tank or ITService Center Environmental ProtectionLimited Warranty USAPage Warranty Card