CMA5000 OTDR Order Guide

This module requires the following open slots:

SBA

MBA

LBA

CMA5000 - OTDR Module Order Guide

The CMA5200 OTDR’s are Single Bay modules that include one OTDR/Source Universal Adapter (UC-130-XX) at no charge. For units with a Power Meter option, a Meter Connector Adapter (LP-XX) is also included at no charge.

52_____-_____ - OTDR - _____

A BC

A = Select an OTDR Module (Additional OTDR modules are available in various combinations of wave lengths and dynamic ranges. Please contact Anritsu for a comprehensive list.)

25 = Singlemode, 37/36 dB dynamic range, dual-wavelength 1310/1550 nm 35 = Singlemode, 40/40 dB dynamic range, dual-wavelength 1310/1550 nm

36 = Singlemode, 40/40/40 dB dynamic range, tri-wavelength 1310/1550/1625 nm 45 = Singlemode, 43/45 dB dynamic range, dual-wavelength 1310/1550 nm

46 = Singlemode, 43/45/43 dB dynamic range, tri-wavelength 1310/1550/1625 nm 54 = Singlemode, 50 dB dynamic range, single-wavelength 1550 nm

60 = Quad 24/26 dB 850/1300 nm 50 µm multimode and 35 dB 1310/1550 nm single mode 61 = Quad 24/26 dB 850/1300 nm 62.5 µm multimode and 35 dB 1310/1550 nm single mode 62 = Quad 24/26 dB 850/1300 nm 62.5 µm multimode and 40 dB 1310/1550 nm single mode 63 = Quad 24/26 dB 850/1300nm 50um multimode and 40/40 dB 1310/1550 nm single mode 66 = Multimode 24/26 dB dynamic range, dual-wavelength 850/1300 nm, 62.5 µm

69 = Multimode 24/26 dB dynamic range, dual-wavelength 850/1300 nm, 50 µm 81 = Singlemode, 37 dB dynamic range, tri-wavelength 1310/1383/1550 nm

83 = Singlemode, 37 dB dynamic range, quad-wavelength 1310/1383/1550/1625 nm 91 = Singlemode, 40 dB dynamic range, tri-wavelength 1310/1490/1550 nm

93 = Singlemode, 37 dB dynamic range, quad wavelegth 1310/1490/1550/1625 nm

B = Select Meter, Light Source and VFL Options (VFL is not available on 5260, 5261 or 5262 module)

000

= No Meter, Light Source or VFL

001

= VFL Only

110

= +10 dBm Meter and Light Source

111

= +10 dBm Meter, Light Source and VFL

210

= +20 dBm Meter and Light Source

211

= +20 dBm Meter, Light Source and VFL

C = Select Connector (APC not available on multimode, all but 60, 61, 62 or 63 optics)

UFC = FC/UPC

AFC = FC/APC

USC = SC/UPC

ASC = SC/APC

UST = ST/UPC

AST = ST/APC

CMA5000 Multi-Layer Test Solution Order Guide

Page 6 of 16

 

 

Image 6
Contents CMA5000 = Select Bay Adapter = Select Drive/Desktop Option CMA5000 Multi-Layer Test Solution Order Guide= Select Power Source = Select Line Cord OptionOptical Accessories CMA5000 SBA and MBA Configuration Table StopXTA 10G CMA5000 Otdr Order Guide CMA5000 Otdr Module Order GuideExample of order number and specifications = Select Base XTA Module CMA5000 XTA Order GuideCMA5000 SDH/SONET XTA Module Order Guide = Select an XTA Module must match base moduleCMA5000 OSA Optical Spectrum Analyzer Module Order Guide = Select ConnectorCMA5000 OSA Order Guide = Select OSA moduleCMA5000 Polarization Mode Dispersion Order Guide PMD moduleOptical sources PMD Artifact = Power cord OptionYY = Connector Option FU = FC/UPC CMA5000 PMD Module and Light Source Order GuideExample of order number and specification CMA5000 Gigabit Ethernet Order GuideCMA5000 Gigabit Ethernet Module Order Guide CMA Ethernet Reflector CMA Ethernet Reflector Order GuideCMA5000 10 Gigabit Ethernet Module Order Guide Optional AccessoriesCMA5000 10 Gigabit Ethernet Order Guide = Select a 10 Gige Module 000 = 10 Gige moduleCMA5000 Otdr Based Chromatic Dispersion Module Order Guide = ConnectorCMA5000 OTDR/Chromatic Dispersion Order Guide = Select a Meter and Light Source OptionsPlease Contact