Model W1784 (Mfg. Since 2/07)
OPERATIONS
Loading
When replacing staples in your Model W1784, follow these guidelines:
Staple Gauge | 15.5 |
Staple Length | |
Capacity: | 60 |
To load your stapler, do these steps:
1.DISCONNECT STAPLER FROM THE AIR SUPPLY!
2.Slide the magazine loading handle back until it locks.
3.Load a staple stick into the magazine
Figure 2. Loading staples into stapler.
4.Pull the magazine loading handle back to unlock it, and slide it forward until the pusher engages the staple stick.
Note: Always control the magazine loading handle when sliding the pusher forward. Allowing the pusher to fly forward against the stapler stick will significantly increase wear of the stapler.
Operating
If you have not read the safety instructions in this manual, do not operate the stapler.
Before you operate your stapler, place five to six drops of the included oil into the quick connect fitting where the stapler connects to the air supply.
The Model W1784 comes with two base plates:
—The thinner base plate is for use with 3⁄4" flooring.
—The thicker base plate is for use with 1⁄2" flooring.
To operate your stapler, do these steps:
1.Install the correct base plate for your size of flooring material.
2.Place the flooring stapler on the floor with the staple discharge facing down, then connect the air supply.
Always point the stapler at the ground when connecting to the air supply. DO NOT aim it in the direction of another person or yourself. Failure to heed this warning could result in serious personal injury.
3.Position a flooring strip and tap it into place with the metal side of the included hammer.