Carrier 38AQS008 specifications Dimensions

Page 4

UNIT

UNIT

UNIT

 

WEIGHT CHART (WITH ALUMINUM COIL)

 

 

WEIGHT CHART (WITH COPPER COIL)

 

W/ALUMINUM COIL

W/COPPER COIL

Std Unit

Corner W

Corner X

Corner Y

Corner Z

Std Unit

Corner W

Corner X

Corner Y

Corner Z

38AQS008

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dim. A

Dim. B

Dim. A

Dim. B

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

 

60 Hz

1-8

1-5

1-912

1-434

540

245

132

60

100

45

133

60

175

80

608

276

160

73

117

53

142

64

189

86

 

[508.0]

[431.8]

[546.0]

[425]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 Hz

1-6

1-7

1-712

1-634

594

270

114

52

114

52

183

83

183

83

662

299

142

64

131

59

192

87

197

89

 

[457.2]

[482.6]

[495.3]

[476.3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1. Dimensions in [ ] are in millimeters.

2. Center of Gravity. See chart for dimensions.

3. Direction of airflow.

4.Minimum clearance (local codes or jurisdiction may prevail):

a.Bottom to combustible surfaces, 0 in. (0 mm)

b.Outdoor coil, for proper airflow, 36 in. (914 mm) one side, 12 in. (305 mm) the other. The side getting the greater clearance is optional.

c.Overhead, 60 in. (1524 mm) to assure proper outdoor-fan operation.

d.Between units, control box side, 42 in. (1067 mm) per National Electrical Code (NEC, U.S.A.).

e.Between unit and ungrounded surfaces, control box side, 36 in. (914 mm) per NEC (U.S.A.).

f.Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in. (1067 mm) per NEC (U.S.A.).

5.With the exception of the clearance for the outdoor coil as stated in note 4b, a removable fence or barricade requires no clearance.

6.Units may be installed on combustible floors made from wood or Class A, B, or C roof covering material.

7.Vertical center of gravity is approximately 40% of total unit height.

 

ELECTRICAL CONNECTIONS

 

 

 

 

 

 

 

 

CONNECTION SIZES

 

AA

 

138Dia. [35] Field Power Supply Hole

BB

 

2Dia. [51] Power Supply Knock-Out

CC

 

212Dia. [64] Power Supply Knock-Out

DD

 

78Dia. [22] Field Control Wiring Hole

 

SERVICE VALVE CONNECTIONS

 

 

 

 

 

 

UNIT

 

SUCTION

 

LIQUID

38AQS008

 

118[28.6]

 

12[12.7]

Fig. 2 — Dimensions

4

Image 4
Contents Safety Considerations ContentsInstallation Rig and Mount the Unit Complete Refrigerant Piping ConnecPhysical Data English Physical Data SIRefrigerant Piping Sizes Make Electrical ConnectionsLiquid Line Data Dimensions Rigging Label Compressor MountingTypical Piping Diagram, 38AQS/40RMQ RLA LRA FLA Electrical DataMAX Fuse or FLA LRA Hacr Brkr Amps Accessory Electric Heater Data 60 Hz Accessory Electric Heater Data 50 HzUnit Heater Heater MCA Mocp 40RMQ Amps→ Control Wiring Connections Fusible Plug LocationsSTART-UP Preliminary ChecksService Outdoor-Fan Adjustment FigChecking Cooling and Heating Control Opera LubricationCooling Mode Operation See Fig Heating Mode Operation See FigCooling Mode Operation Troubleshooting CHART, Cooling Cycle Troubleshooting CHART, Heating Cycle Page Page Copyright 1995 Carrier Corporation Preliminary Information START-UP ChecklistPre-Start-Up Start-Up

38AQS008 specifications

The Carrier 38AQS008 is a high-performance air conditioning unit that stands out for its innovative technology, design, and efficiency. As part of Carrier's extensive line of HVAC solutions, this model is engineered to deliver optimal indoor comfort while minimizing energy consumption.

One of the main features of the Carrier 38AQS008 is its high SEER rating, which signifies exceptional energy efficiency. This rating ensures that consumers can enjoy lower utility bills and reduced environmental impact, making it an ideal choice for eco-conscious homeowners. The unit's advanced cooling technologies work seamlessly to maintain precise temperature control, ensuring a pleasant environment regardless of the season.

The Carrier 38AQS008 employs a variable-speed compressor, which allows the system to adjust its operation based on the cooling demand. Unlike traditional fixed-speed units that operate at a single speed, the variable-speed technology leads to quieter operation, increased efficiency, and improved dehumidification. As the unit operates at lower speeds, it can effectively reduce energy usage when full cooling capacity is not required, further enhancing overall efficiency.

In addition to its potent cooling capabilities, the Carrier 38AQS008 incorporates a robust filtration system that captures airborne particles, dust, and allergens. This feature not only improves indoor air quality but also ensures that the system operates efficiently by maintaining clean coils. Users can enjoy a healthier living space while also prolonging the lifespan of the air conditioning unit.

Another characteristic of the Carrier 38AQS008 is its durable construction, designed to withstand harsh weather conditions. The unit is equipped with a galvanized steel cabinet that offers corrosion resistance, and its compact design allows for easy installation and integration into various home environments.

Moreover, the Carrier 38AQS008 is compatible with smart home technology, allowing users to control their air conditioning system remotely. This feature enhances convenience and efficiency, as homeowners can adjust settings based on their daily routines and preferences.

Meeting rigorous energy performance standards, the Carrier 38AQS008 exemplifies Carrier's commitment to sustainability and customer satisfaction. With its combination of advanced features, reliable performance, and user-friendly technology, this air conditioning unit is a superior choice for those seeking a dependable and efficient cooling solution.