OPERATING INSTRUCTIONS

USING THE TOOL

Complete all steps of PREPARING THE TOOL before using the tool.

This tool is shipped from the factory with a “single sequential actuation” trigger. This actuation design requires the release of both the trigger and safety mechanism after each fastener is driven. Sequential actuation is the only triggering option available for this tool. To fire, grip the tool firmly to maintain control, position nose of tool onto work surface, push the tool firmly against work surface to depress safety (S) Fig. 24, and squeeze trigger to fire a fastener. Allow tool to recoil away from work surface as fastener is driven. This “single sequential actuation” method provides the most accurate fastener placement.

Disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person.

Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair.

Fig. 24

S

 

RUBBER NOSE CUSHION

A rubber nose cushion (A) Fig. 25 is provided to reduce marring of the work surface. The rubber cushion can be removed when it is not required.

Disconnect tool from air supply before removing or installing rubber cushion.

A

Fig. 25

9

Image 9
Contents Español Página Française StaplersTable of Contents Important Safety Instructions Safety Guidelines / DefinitionsGeneral Safety Rules Page Page Carton Contents EMPLOYER’S ResponsibilitiesFunctional Description Preparing the Tool Using the Tool Operating InstructionsRubber Nose Cushion Maintenance Clean and Inspect DailyClearing a Jammed Fastener Service Troubleshooting GuideService and Repairs Responsibility of Original Purchaser initial User Warranty