Bogen CMP1R specifications Module Installation, Jumper Selections, Module Features

Page 2

Module Installation

1. Turn off all power to the unit.

2.Make all necessary jumper selections.

3.Position module in front of desired output module bay opening, making sure that the module is right-side up. Output modules will not fit in input module bays. Do not force an output module into an input module bay.

4.Slide module on to card guide rails. Make sure that both the top and bottom guides are engaged.

5.Push the module in to the bay until the faceplate con- tacts the unit’s chassis.

6.Use the two screws included to secure the module to the unit.

WARNING:

Turn off power to unit and make all jumper selections before installing module in unit.

Jumper Selections

Priority Level

Jumper placement only affects the unbalanced input signal. The jumper placement determines whether the module’s input can be muted by other input modules. When enabled, the input is per- manently set to the lowest priority level.

Hard / Soft Knee Jumpers

For “brick wall” limiting and hard knee compression, set the J32 jumper to ‘Hard.’ For soft knee compression, set the J32 jumper to ‘Soft.’

Module Features

When set to lower compression levels, the CMP1R can be used as a compressor to minimize the differences in level of all of the inputs on the mix bus, or, when set to maximum compression, it can be used as a limiter to keep overall output at a desired level.

All Bogen output modules include an unbalanced input that is controlled by the amplifier’s input control so that the user is not penalized in number of inputs when using an output module.

Compression Ratio

The compression ratio control is adjustable in order to alter the dynamics of the signal above the limiting threshold. In the minimum position, the action of the compressor is light (compression ratio 2:1, approximately), thereby resulting in mild compression. The maximum position provides “brick wall” limiting (infinite compression ratio), where no further increase above the threshold level will occur in the output signal.

Input

The RCA unbalanced input provides a 20k-ohm input impedance.The unbal- anced input connects to the amplifier’s front level control for the bay in which it is installed so that the input is not lost when using the output mod- ule.

Threshold

Controls the minimum necessary mix bus signal level to trigger the module to begin compression. Clockwise rotation increases the necessary signal level required to trigger compression. The threshold is adjustable from -40dBV to +10dBV with the center of rotation being approximately -10dBV.

Make-Up Gain

Provides additional gain after the signal has been compressed to reestablish the nominal system signal level. The make-up gain has a range of 0dB (unity gain) to +15dB. Care should be taken not to overdrive the amplifier’s input when applying this additional gain.

Compressor Bypass Switch

The Compressor Bypass Switch provides instant comparison between com- pression and no compression during the tuning of the system.

Image 2
Contents Features CMP1RJumper Selections Module InstallationModule Features Block Diagram

CMP1R specifications

The Bogen CMP1R is a versatile and highly efficient public address (PA) system designed to cater to a variety of commercial audio needs. Known for its exceptional performance, the CMP1R provides powerful sound amplification paired with user-friendly features, making it an ideal choice for schools, offices, warehouses, and retail environments.

One of the standout features of the CMP1R is its robust, 70V/100V line transformer that provides flexibility for large-scale audio distribution. This allows the system to effectively cover extensive areas while maintaining audio clarity. With a power output of up to 120 watts, the CMP1R is capable of delivering clear and impactful sound to a broad audience, ensuring that messages are heard loud and clear.

The amplifier section of the CMP1R incorporates advanced technologies such as protected circuitry to prevent overheating and enhance reliability. This makes the system durable and suitable for continuous operation, which is essential in environments where announcements must be made frequently. The internal circuitry is designed to minimize distortion, offering crystal-clear reproduction of speech and music alike.

User-friendliness is another hallmark of the Bogen CMP1R. Its intuitive interface allows users to easily adjust volume levels and select different input sources, including microphones and other audio devices. The system is equipped with multiple input options, such as line-level, mic-level, and auxiliary inputs, granting users the flexibility to connect various audio sources seamlessly.

Additionally, the CMP1R features built-in equalization controls that enable users to tailor audio output according to specific acoustical environments. This is crucial for ensuring optimal sound performance regardless of the setting.

The installation process of the Bogen CMP1R is straightforward, complemented by its compact design that allows for easy integration into existing PA systems. Its durable construction ensures long-lasting performance, catering to both indoor and outdoor applications.

In summary, the Bogen CMP1R is an impressive public address solution offering powerful sound amplification, advanced protection technology, user-friendly operation, and flexible connectivity options. It stands out as a reliable option for enhancing communication in various commercial settings.