Encore electronic (66-501-1) instruction manual Before Starting, Before Each Start-Up

Page 13

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "OFF".

Before Starting

Break-in Procedure

Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not

closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "Off" position.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counterclockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF".

2.Pull regulator knob out, turn counterclockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet

pressure must never exceed the maximum pressure rating.

13- ENG

A08591

Image 13
Contents Oil-Free Air Compressor Important Safety Instructions Safety Guidelines DefinitionsDeath or serious injury Or moderate injury Death or serious injuryAlways remain in attendance with What Could HappenAttachments & Accessories Repairs attempted by unqualified Electricity. Like any other electricallyTo human consumption Your specific applicationHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesAccessories SpecificationsGlossary Duty CycleInstallation AssemblyLocation of the Air Compressor Extension Cords Grounding InstructionsVoltage and Circuit Protection Know Your Air Compressor Description of Operation OperationRegulator Check ValveBefore Each Start-Up Before StartingHow to Start MaintenanceTo Check Safety Valve Customer ResponsibilitiesTo Replace or Clean Check Valve Service and AdjustmentsOutlet Tube Screwdriver Open position nothing is visibleTo Replace Regulator StorageProblem Cause Correction TroubleshootingBeing used Problem Cause Correction AIR Compressor Diagram Part Number Description Parts ListAIR Compressor Pump Diagram Not Illustrated Key DescriptionResponsibility of Original Purchaser initial User Limited Warranty