Fedders Room Air Conditioners Installation/Troubleshooting, Chassis Installation

Page 3

Chassis Installation

1.Remove front closure panel. Remove Z-bracket by loosening sup- port screw (Fig. 1).

2.Remove the rear louver panel and rear closure panel through the inside of the sleeve by removing the screws. Reinstall rear louver panel in the sleeve (Fig. 2).

3.If time has elapsed since the sleeve was installed, recheck level for 1/2 bubble outward pitch.

4.Slide chassis into sleeve as far as possible.

5.Attach decorative front (sold separately). DO NOT OPERATE THE AIR CONDITIONER WITHOUT THE DECORATIVE FRONT.

If you are installing this unit into an existing Fedders sleeve, please com- pare the depth of your existing sleeve and the depth of your new unit. If you are installing the “A” size unit into the deeper “B” sleeve, adapter kit AXB005AB (sold separately) must be used. If you are installing the “B” size unit into the shallower “A” sleeve, adapter kit AXA00A2B (sold separately) must be used. These kits are designed to provide maximum efficiency and proper installation of the unit without having to remove and replace your existing Fedders sleeve.

WARNING

These panels cannot be removed from outside of structure.

Use caution when working around exposed sharp edges of the cabinet and sharp coils to avoid injury or torn clothing.

Proper use and care of your air conditioner will help ensure longer life of the unit. It is recommended to

annually inspect and clean the coils and condensate water passages. Expense of annual inspection is the consumers’ responsibilities.

Troubleshooting

To save time and expense, check the following before calling an authorized service station.

Insufficient Cooling

pTurn Master Control to OFF.

pShut all windows and doors in room.

pRemove any obstructions from inside and outside cabinet louvers.

pInspect filter and clean if dirty.

pTurn Temperature Control to COOLER.

pTurn Master Control to HIGH COOL.

Under certain conditions the cooling coils directly behind the filter, may ice up and block the airflow. This is a common occurrence in air condi- tioners caused when the outside temperature drops below 70°F (21°C) while the humidity remains high. If this happens, simply turn the unit off and allow the ice to melt, then resume normal operation.

Unit Fails to Start

pTurn Master Control to OFF.

pReplug line cord plug into outlet to be sure electrical contact is being made. (If firm contact is not being made, outlet may have to be replaced).

pTurn Master Control to HIGH FAN. If air circulating fan does not operate, check house circuit breaker (or fuses).

Installation/Troubleshooting

1

Support screw

 

 

 

 

 

 

 

Z-bracket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

Rear louver panel

Rear closure panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ScrewsSleeve

WARNING

This unit should only be installed by a qualified

HVAC technician in accordance with the National

Electrical Code and local codes and ordinances.

Failure to follow these precautions could result in electrical shock, fire, death or serious personal injury.

2

Image 3
Contents Directives de sécurité important InstallationInstalación Localización y Solución de averíasOr email customerservice@fedders.com Important Safety InstructionsInsufficient Cooling Installation/TroubleshootingChassis Installation TroubleshootingRoom Air Conditioner Warranty Warranty How to Obtain Warranty Service or PartsPuesta a Tierra Instrucciones importantes de seguridadRiesgo de Choque Eléctrico Requerimientos Importantes ParaAdvertencia Instalación / Localización y solución de averíasInstalación del chasis Localización y Solución de averíasGarantía Completa de Un Año para Repuestos y Mano de Obra GarantíaCómo Obtener Servicio o Repuestos Bajo la Garantía Garantía del Acondicionador de Aire IndividualAvertissement Directives de sécurité importantRisque de choc électrique Cordon électrique avec dispositif de détection darcRefroidissement insuffisant Installation / Guide de diagnosticInstallation du châssis Guide de diagnosticGarantie totale un an Pièces et main-d’oeuvre Obtention de pièces ou de services au titre de la garantieGarantie Garantie du climatiseurPage Features and specifications subject to change without notice

Room Air Conditioners specifications

Fedders Room Air Conditioners are renowned for their reliable performance and efficiency in cooling residential and commercial spaces. As a brand with a significant history in the HVAC (heating, ventilation, and air conditioning) industry, Fedders has developed a range of room air conditioners that cater to diverse cooling needs. These units are designed to provide comfort while maximizing energy efficiency, making them a popular choice among consumers.

One of the key features of Fedders Room Air Conditioners is their ease of installation. Many models are designed for straightforward window or wall mounting, allowing homeowners to set up their units without professional assistance. This flexibility is complemented by compact designs that fit a variety of window sizes and types, making them suitable for numerous applications.

Energy efficiency is paramount in today's eco-conscious landscape, and Fedders has equipped its air conditioners with technologies that reduce energy consumption while maintaining excellent cooling performance. Many units come with Energy Star ratings, indicating that they meet strict energy efficiency guidelines set by the US Environmental Protection Agency. This not only helps consumers save on electricity bills but also contributes to a reduced environmental impact.

Fedders Room Air Conditioners often feature adjustable thermostat settings, allowing users to customize their cooling experience based on personal preferences. Additionally, models equipped with remote controls provide added convenience, enabling users to manage settings from a distance. Multiple fan speeds and modes, including cooling, fan-only, and dehumidification modes, offer versatility for various weather conditions and personal comfort levels.

Another important characteristic of Fedders air conditioners is their low noise operation. Designed with sound-dampening technology, these units operate quietly, ensuring minimal disruption in living areas, bedrooms, or offices. Innovative engineering also helps in efficient heat exchange and reduced vibrations, further enhancing user comfort.

Durability and build quality are vital factors in the longevity of air conditioning units. Fedders emphasizes using durable materials and corrosion-resistant components to ensure that their units withstand the test of time, even in varying climates. Regular maintenance reminders and easy-access filters also contribute to the longevity and performance of the air conditioners, helping users to maintain optimal efficiency.

In summary, Fedders Room Air Conditioners combine practicality, efficiency, and comfort in one package. With innovative features, energy-efficient technologies, and a commitment to quality, Fedders continues to be a reliable choice for anyone seeking effective cooling solutions in their spaces.