Lightolier C7P38MH specifications 1 of 212 Aperture, ED28 Enclosed Metal Halide, Wide Beam

Page 2

Calculite® HID Downlight C12E28VW

Page 1 of 212" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam

175W ED28 G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM

1,375

2,750

4,125

5,500

*** EFFICIENCY = 61.8% ** SC = 1.1

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

5034

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

5057

489

45

 

72490

CEILING

 

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

5362

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

3628

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

 

15

5266

1459

 

 

 

 

65

 

0

 

 

60°

20

4701

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

25

4237

1967

 

 

 

 

30

3820

 

5

 

0

 

 

0

.74

.74

.74

.74

.72

.72

.69

.69

.66

.66

 

.62

 

35

3715

2249

 

 

 

 

 

1

.70

.68

.67

.65

.67

.64

.64

.62

.62

.60

 

.58

 

40

3070

 

ZONAL LUMENS AND PERCENTAGES

 

2

.67

.64

.61

.59

.63

.58

.60

.57

.59

.56

 

.54

 

45

2096

1574

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.63

.59

.56

.53

.58

.53

.57

.52

.55

.51

 

.50

 

50

866

 

0-30

3915

30.35

49.12

 

4

.60

.55

.52

.49

.54

.49

.53

.48

.52

.48

 

.46

 

55

85

233

0-40

6164

47.79

77.33

 

 

 

 

5

.56

.51

.47

.45

.50

.44

.49

.44

.48

.44

 

.42

 

60

2

 

0-60

7970

61.79

99.99

 

 

 

65

0

1

0-90

7971

61.79

100

 

6

.53

.47

.44

.41

.47

.41

.46

.40

.45

.40

 

.39

 

70

0

 

40-90

1807

14.01

22.67

 

7

.50

.44

.40

.37

.43

.37

.42

.37

.42

.36

 

.35

 

75

0

0

60-90

0

0

0.01

 

8

.47

.40

.36

.34

.40

.33

.39

.33

.39

.33

 

.32

 

90-180

0

0

0

 

 

 

80

0

 

0-180

7971

61.79

100

 

9

.44

.37

.33

.30

.37

.30

.36

.30

.36

.30

 

.29

30°

8

5

0

 

 

 

 

 

10

.41

.34

.30

.27

.34

.27

.33

.27

.33

.27

 

.26

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 205.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2505FR, DATE: MAR 14, 2004

COMPUTED BY LSI PROGRAM **TEST-LITE**

250W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM

2,125

4,250

6,375

8,500

** EFFICIENCY = 62.4% ** SC = 1.1

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

8217

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

8229

788

45

 

105132

CEILING

 

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

8325

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

5546

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

 

15

8132

2277

 

 

 

 

65

 

0

 

 

60°

20

7546

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

75

 

0

 

 

 

25

6737

3109

 

 

 

 

30

5850

 

85

 

0

 

 

0

.74

.74

.74

.74

.73

.73

.69

.69

.66

.66

 

.62

 

35

5457

3333

 

 

 

 

 

1

.71

.69

.67

.66

.68

.65

.65

.63

.63

.61

 

.58

 

40

4459

 

ZONAL LUMENS AND PERCENTAGES

 

2

.67

.64

.62

.60

.63

.59

.61

.58

.59

.57

 

.54

 

45

3040

2289

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.64

.60

.57

.54

.59

.54

.57

.53

.56

.52

 

.50

 

50

1286

 

0-30

6174

31.7

50.84

 

4

.61

.56

.52

.50

.55

.49

.54

.49

.53

.48

 

.47

 

55

130

348

0-40

9507

48.82

78.28

 

 

 

 

5

.57

.52

.48

.45

.51

.45

.50

.45

.49

.44

 

.43

 

60

4

 

0-60

12143

62.36

99.99

 

 

 

65

0

1

0-90

12144

62.36

100

 

6

.54

.48

.44

.42

.48

.42

.47

.41

.46

.41

 

.40

 

70

0

 

40-90

2637

13.54

21.72

 

7

.51

.45

.41

.38

.44

.38

.43

.38

.43

.37

 

.36

 

75

0

0

60-90

0

0

0.01

 

8

.48

.41

.37

.35

.41

.34

.40

.34

.40

.34

 

.33

 

90-180

0

0

0

 

 

 

80

0

 

0-180

12144

62.36

100

 

9

.45

.38

.34

.31

.38

.31

.37

.31

.37

.31

 

.30

30°

85

0

0

 

 

 

 

 

10

.42

.35

.31

.28

.35

.28

.34

.28

.34

.28

 

.27

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 290.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2508FR, DATE: MAR 14, 2004

COMPUTED BY LSI PROGRAM **TEST-LITE*

320W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 30100 LMS, ADVANCE BALLAST PULSE START MAGNETIC, CL FINISH TRIM

2,750

5,500

8,250

11,000

***EFFICIENCY = 55.7% ** SC = 1.2

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

10325

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

10384

994

45

 

92020

CEILING

 

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

10573

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

4756

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

 

15

10304

2894

 

 

 

 

65

 

0

 

 

60°

20

9659

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

25

8898

4099

 

 

 

 

30

7970

 

85

 

0

 

 

0

.66

.66

.66

.66

.65

.65

.62

.62

.59

.59

 

.56

 

35

7756

4746

 

 

 

 

 

1

.63

.62

.60

.59

.60

.58

.58

.56

.56

.54

 

.52

 

40

6738

 

ZONAL LUMENS AND PERCENTAGES

 

2

.60

.57

.55

.53

.56

.52

.54

.51

.53

.50

 

.48

 

45

4730

3513

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.57

.53

.50

.48

.52

.48

.51

.47

.50

.46

 

.45

 

50

1945

 

0-30

7987

26.54

47.62

 

4

.54

.49

.46

.44

.49

.43

.48

.43

.46

.43

 

.41

 

55

198

526

0-40

12733

42.3

75.92

 

 

 

 

5

.51

.46

.42

.40

.45

.40

.44

.39

.43

.39

 

.38

 

60

4

 

0-60

16771

55.72

99.99

 

 

 

65

0

1

0-90

16772

55.72

100

 

6

.48

.42

.39

.36

.42

.36

.41

.36

.40

.36

 

.35

 

70

0

 

40-90

4039

13.42

24.08

 

7

.45

.39

.35

.33

.39

.33

.38

.33

.37

.32

 

.31

 

75

0

0

60-90

1

0

0.01

 

8

.42

.36

.32

.30

.35

.30

.35

.30

.34

.29

 

.28

 

90-180

0

0

0

 

 

 

80

0

 

0-180

16772

55.72

100

 

9

.39

.33

.29

.27

.33

.27

.32

.27

.32

.26

 

.26

30°

85

0

0

 

 

 

 

 

10

.36

.30

.27

.24

.30

.24

.29

.24

.29

.24

 

.23

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 370.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2413FR, DATE: FEB 10, 2004

COMPUTED BY LSI PROGRAM **TEST-LITE**

400W ED28 G.E. MH COATED LAMP. LUMEN RATING = 35000 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM

5,000

10,000

15,000

20,000

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

14097

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

14418

1399

45

 

207807

CEILING

 

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

15675

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

5858

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

 

15

15612

4282

 

 

 

 

65

 

0

 

 

60°

20

13529

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

25

11653

5440

 

 

 

 

 

 

 

85

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

10175

 

 

 

 

.76

.76

.76

.76

.75

.75

.71

.71

.68

.68

 

.64

 

35

10432

6250

 

 

 

 

 

1

.73

.71

.69

.68

.70

.67

.67

.65

.65

.63

 

.60

 

40

8760

 

ZONAL LUMENS AND PERCENTAGES

 

2

.69

.66

.64

.61

.65

.61

.63

.59

.61

.58

 

.56

 

45

6008

4499

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.66

.61

.58

.56

.61

.55

.59

.54

.57

.54

 

.52

 

50

2461

614

0-30

11120

31.77

49.46

 

4

.62

.57

.54

.51

.57

.51

.55

.50

.54

.50

 

.48

 

55

137

0-40

17370

49.63

77.26

 

5

.59

.53

.49

.46

.53

.46

.51

.46

.50

.45

 

.44

 

60

0

 

0-60

22483

64.24

100

 

 

 

 

 

6

.55

.49

.45

.43

.49

.42

.48

.42

.47

.42

 

.41

 

65

0

0

0-90

22483

64.24

100

 

 

 

40-90

5112

14.61

22.74

 

7

.52

.46

.42

.39

.45

.38

.44

.38

.43

.38

 

.37

 

70

0

 

 

 

 

 

60-90

0

0

0

 

8

.49

.42

.38

.35

.42

.35

.41

.35

.40

.35

 

.34

 

75

0

0

 

 

 

90-180

0

0

0

 

9

.46

.39

.35

.32

.38

.32

.38

.32

.37

.31

 

.30

 

80

0

 

0-180

22483

64.24

100

 

 

30°

85

0

0

 

 

 

 

 

10

.43

.36

.32

.29

.35

.29

.35

.29

.34

.28

 

.27

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 64.2% ** SC = 1.1

CERTIFIED TEST REPORT NO. 2521FR, DATE: MAR 14, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINAIRE INPUT WATTS = 460

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4

Image 2
Contents Frame-In Kit FeaturesOptions and Accessories Electrical1 of 212 Aperture, ED28 Enclosed Metal Halide, Wide Beam