Lightolier CFH2GPF2FT, CFH2GPF3FT Ordering Information, Options/Accessories, Specifications

Page 2

Coffaire II Recessed Fluorescent CFH2GP2FT or 3FT

Page 2 of 2

Direct/Indirect – 2' x 2' with Perforated Basket Air Handling/Static, 2 Lamp or 3 Lamp, Twin Tube T5

Model No. CFH2GPF2FT120SB

LER = FP - 56.2 IW - 65.5 BF - 0.86 Comparative yearly lighting energy cost per

1000 lumens = $4.27

Report Number: G2004033

Catalog Number: CFH2GPF2FT120SB

Lamps: F40 30BX/SPX35

Luminaire: Coffaire II with perforated basket

Ballast: Triad C240SI120

Report is based on 3150 Lumens per lamp. Efficiency: 68.1%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

74

71

68

66

64

62

64

62

60

02

67

62

57

58

54

51

56

53

50

03

61

54

48

51

46

43

49

45

42

04

56

48

41

45

40

36

43

39

36

05

51

42

36

40

35

31

39

34

31

06

47

38

32

36

31

27

35

30

27

07

44

34

28

33

28

24

32

27

24

08

41

31

25

30

25

21

29

24

21

09

38

29

23

28

23

19

27

22

19

10

36

26

21

25

21

17

25

20

17

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

3742.

4271.

4713.

55

3440.

4340.

4880.

65

2952.

4236.

4641.

75

2279.

3362.

3419.

85

1252.

1794.

1895.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1423

1423

1423

 

5

1416

1416

1417

135

15

1354

1369

1385

387

25

1242

1283

1331

593

35

1089

1168

1251

732

45

897

1024

1130

786

55

669

844

949

738

65

423

607

665

569

75

200

295

300

290

85

37

53

56

61

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1115

17.7

26.0

00-040

1847

29.3

43.1

00-060

3370

53.5

78.6

00-090

4289

68.1

100.0

90-180

0000

0.0

000.0

00-180

4289

68.1

100.0

Model No. CFH2GPF3FT120X3

LER = FP - 41.2 IW - 111.1 BF - 0.88 Comparative yearly lighting energy cost per

1000 lumens = $5.85

Report Number: G2004247

Catalog Number: CFH2GPF3FT120X3

Lamps: F40/TT5

Luminaire: Coffaire II with perforated basket

Ballast: UT340120

Report is based on 3150 Lumens per lamp. Efficiency: 55.2%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

60

58

55

54

52

51

52

51

49

02

55

50

47

47

45

42

46

43

41

03

50

44

40

42

38

35

40

37

35

04

46

39

34

37

33

30

36

32

30

05

42

35

30

33

29

26

32

29

26

06

39

32

27

30

26

23

29

25

23

07

36

29

24

27

23

20

26

23

20

08

34

26

21

25

21

18

24

21

18

09

31

24

19

23

19

16

22

19

16

10

29

22

18

21

17

15

21

17

15

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4588.

5247.

5781.

55

4093.

5117.

5785.

65

3308.

4788.

5255.

75

2484.

3407.

3715.

85

1354.

1658.

1692.

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

1878

1878

1878

 

5

1848

1861

1878

177

15

1746

1789

1826

506

25

1582

1658

1726

766

35

1364

1479

1582

927

45

1100

1258

1386

966

55

796

995

1125

874

65

474

686

753

641

75

218

299

326

304

85

40

49

50

59

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1449

15.3

27.8

00-040

2376

25.1

45.5

00-060

42316

44.6

80.8

00-090

5219

55.2

100.0

90-180

0000

00.0

000.0

00-180

5219

55.2

100.0

Ordering Information

Explanation of Catalog Number. Example: CFH2GPF2FT120SB

 

 

 

 

 

 

 

 

2

 

G

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffaire II:

 

Body Style:

Fixture

Ceiling

Type:

Perforated

 

Direct/

S = Static

Width

 

Fits both

Lamp

 

Indirect:

H = Air Return

 

 

Standard Grid

Shield

 

Recessed

 

 

 

 

 

 

 

and

 

 

with Perforated

 

 

 

Slot Grid

 

 

Mesh Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

CF

Standard Coffaire II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CY

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

F

Flat

White

Reflector

FT

LampLamp:

Quantity (By Others)

2=2 Lamp

3=3 Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

Options:

120, 277 or

 

Add appropriate

UNV=120-277

 

suffix to catalog

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

Ballast Type:

<10THD

 

 

 

 

<20THD

1-2 Lamp Elec. TT5

SB *

IB *

 

(40 Watt)

 

 

 

I3 *

1-3 Lamp Elec. TT5

 

X3 *

 

(40 Watt)

 

 

 

 

 

 

LOL Dimming TT5

 

PB*

 

*Instant Start Standard

Other dimming options. Consult factory.

NOTE:

For TT5 UNV, you must use IB, I3 Ballast Code.

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X2 and CF2FK SPACER.

Electrical Wiring Options: Consult factory.

Chicago Plenum: SUFFIX C.

Specifications

Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 4641 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.0%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Specifications (continued)

Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Reflector – baked white post painted acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2005 a Genlyte company

Section 5/Folio M15-25

Image 2
Contents Features Mounting MethodsOrdering Information Options/AccessoriesSpecifications