Coffaire II Recessed Fluorescent CFH2GP2FT or 3FT
Page 2 of 2
Direct/Indirect – 2' x 2' with Perforated Basket Air Handling/Static, 2 Lamp or 3 Lamp, Twin Tube T5
Model No. CFH2GPF2FT120SB
LER = FP - 56.2 IW - 65.5 BF - 0.86 Comparative yearly lighting energy cost per
1000 lumens = $4.27
Report Number: G2004033
Catalog Number: CFH2GPF2FT120SB
Lamps: F40 30BX/SPX35
Luminaire: Coffaire II with perforated basket
Ballast: Triad C240SI120
Report is based on 3150 Lumens per lamp. Efficiency: 68.1%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 22.920 |
| 22.920 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 74 | 71 | 68 | 66 | 64 | 62 | 64 | 62 | 60 |
02 | 67 | 62 | 57 | 58 | 54 | 51 | 56 | 53 | 50 |
03 | 61 | 54 | 48 | 51 | 46 | 43 | 49 | 45 | 42 |
04 | 56 | 48 | 41 | 45 | 40 | 36 | 43 | 39 | 36 |
05 | 51 | 42 | 36 | 40 | 35 | 31 | 39 | 34 | 31 |
06 | 47 | 38 | 32 | 36 | 31 | 27 | 35 | 30 | 27 |
07 | 44 | 34 | 28 | 33 | 28 | 24 | 32 | 27 | 24 |
08 | 41 | 31 | 25 | 30 | 25 | 21 | 29 | 24 | 21 |
09 | 38 | 29 | 23 | 28 | 23 | 19 | 27 | 22 | 19 |
10 | 36 | 26 | 21 | 25 | 21 | 17 | 25 | 20 | 17 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 3742. | 4271. | 4713. |
55 | 3440. | 4340. | 4880. |
65 | 2952. | 4236. | 4641. |
75 | 2279. | 3362. | 3419. |
85 | 1252. | 1794. | 1895. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1423 | 1423 | 1423 |
|
5 | 1416 | 1416 | 1417 | 135 |
15 | 1354 | 1369 | 1385 | 387 |
25 | 1242 | 1283 | 1331 | 593 |
35 | 1089 | 1168 | 1251 | 732 |
45 | 897 | 1024 | 1130 | 786 |
55 | 669 | 844 | 949 | 738 |
65 | 423 | 607 | 665 | 569 |
75 | 200 | 295 | 300 | 290 |
85 | 37 | 53 | 56 | 61 |
90 | 0 | 0 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1115 | 17.7 | 26.0 | |
1847 | 29.3 | 43.1 | |
3370 | 53.5 | 78.6 | |
4289 | 68.1 | 100.0 | |
0000 | 0.0 | 000.0 | |
4289 | 68.1 | 100.0 |
Model No. CFH2GPF3FT120X3
LER = FP - 41.2 IW - 111.1 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.85
Report Number: G2004247
Catalog Number: CFH2GPF3FT120X3
Lamps: F40/TT5
Luminaire: Coffaire II with perforated basket
Ballast: UT340120
Report is based on 3150 Lumens per lamp. Efficiency: 55.2%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 22.920 |
| 22.920 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 60 | 58 | 55 | 54 | 52 | 51 | 52 | 51 | 49 |
02 | 55 | 50 | 47 | 47 | 45 | 42 | 46 | 43 | 41 |
03 | 50 | 44 | 40 | 42 | 38 | 35 | 40 | 37 | 35 |
04 | 46 | 39 | 34 | 37 | 33 | 30 | 36 | 32 | 30 |
05 | 42 | 35 | 30 | 33 | 29 | 26 | 32 | 29 | 26 |
06 | 39 | 32 | 27 | 30 | 26 | 23 | 29 | 25 | 23 |
07 | 36 | 29 | 24 | 27 | 23 | 20 | 26 | 23 | 20 |
08 | 34 | 26 | 21 | 25 | 21 | 18 | 24 | 21 | 18 |
09 | 31 | 24 | 19 | 23 | 19 | 16 | 22 | 19 | 16 |
10 | 29 | 22 | 18 | 21 | 17 | 15 | 21 | 17 | 15 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 4588. | 5247. | 5781. |
55 | 4093. | 5117. | 5785. |
65 | 3308. | 4788. | 5255. |
75 | 2484. | 3407. | 3715. |
85 | 1354. | 1658. | 1692. |
CANDELA DISTRIBUTION0
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1878 | 1878 | 1878 |
|
5 | 1848 | 1861 | 1878 | 177 |
15 | 1746 | 1789 | 1826 | 506 |
25 | 1582 | 1658 | 1726 | 766 |
35 | 1364 | 1479 | 1582 | 927 |
45 | 1100 | 1258 | 1386 | 966 |
55 | 796 | 995 | 1125 | 874 |
65 | 474 | 686 | 753 | 641 |
75 | 218 | 299 | 326 | 304 |
85 | 40 | 49 | 50 | 59 |
90 | 0 | 0 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1449 | 15.3 | 27.8 | |
2376 | 25.1 | 45.5 | |
42316 | 44.6 | 80.8 | |
5219 | 55.2 | 100.0 | |
0000 | 00.0 | 000.0 | |
5219 | 55.2 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: CFH2GPF2FT120SB
|
|
|
|
|
|
|
| 2 |
| G |
| P | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Coffaire II: |
| Body Style: | Fixture | Ceiling | Type: | Perforated | ||||||||
| Direct/ | S = Static | Width |
| Fits both | Lamp | |||||||||
| Indirect: | H = Air Return |
|
| Standard Grid | Shield | |||||||||
| Recessed |
|
|
|
|
|
|
| and |
|
| ||||
with Perforated |
|
|
| Slot Grid |
|
| |||||||||
Mesh Shield |
|
|
|
|
|
|
|
|
|
|
|
| |||
| CF | Standard Coffaire II |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||||
| CY |
| For NYC Code – I.B.E.W. Manufactured |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||||||
| CN | For NYC Code – Local 3 Manufactured |
|
|
|
|
|
|
F
Flat
White
Reflector
FT
LampLamp:
Quantity (By Others)
2=2 Lamp
3=3 Lamp
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: |
|
|
| Options: | |||||
120, 277 or |
| Add appropriate | |||||||
| suffix to catalog | ||||||||
|
|
|
|
|
| no., ie: (GLR) | |||
|
|
| Ballast Type: | <10THD | |||||
|
|
|
| <20THD | |||||
SB * | IB * | ||||||||
| (40 Watt) |
|
|
| I3 * | ||||
| X3 * | ||||||||
| (40 Watt) |
|
|
|
|
|
| ||
LOL Dimming TT5 |
| PB* |
| – |
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For TT5 UNV, you must use IB, I3 Ballast Code.
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2 and CF2FK SPACER.
Electrical Wiring Options: Consult factory.
Chicago Plenum: SUFFIX C.
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 4641 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Specifications (continued)
Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Reflector – baked white post painted acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Job Information | Type: |
|
|
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978) | |
631 Airport Road, Fall River, MA 02720 • (508) | |
We reserve the right to change details of design, materials and finish. | |
© 2005 a Genlyte company | Section 5/Folio |