Sealatron Enclosed Industrial Fluorescent STW Series
Page 2 of 2
Wet/Damp Locations, Rapid Start, Slimline/ High Output, 1 or 2 Lamp T5 or T8
Model No. ST4WA232120SO
LER = FP - 67.9 IW - 53.8 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: G97030
Catalog Number: ST4WA232120SO
Lamps: F32T8
Luminaire: Sealatron, enclosed industrial with 25% high impact DR acrylic lens for wet/damp locations.
Ballast: Triad B232I120RH
Report is based on 2850 Lumens per lamp. Efficiency: 74.8%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
|
| |||
Spacing Criteria: |
|
| 1.2 |
|
| 1.5 | |||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 77 | 72 | 68 | 65 | 62 | 59 | 60 | 58 | 56 |
02 | 69 | 62 | 56 | 55 | 51 | 47 | 51 | 48 | 44 |
03 | 62 | 54 | 47 | 48 | 43 | 38 | 45 | 40 | 37 |
04 | 57 | 47 | 40 | 42 | 37 | 32 | 39 | 35 | 31 |
05 | 52 | 42 | 35 | 38 | 32 | 27 | 35 | 30 | 26 |
06 | 48 | 37 | 30 | 34 | 28 | 24 | 32 | 27 | 23 |
07 | 44 | 34 | 27 | 31 | 25 | 21 | 29 | 24 | 20 |
08 | 41 | 31 | 24 | 28 | 22 | 18 | 28 | 21 | 18 |
09 | 38 | 28 | 22 | 26 | 20 | 17 | 24 | 19 | 16 |
10 | 36 | 26 | 20 | 24 | 18 | 15 | 22 | 18 | 14 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 3724. | 4172. | 4301. |
55 | 3281. | 4097. | 4315. |
65 | 2750. | 4122. | 4496. |
75 | 2152. | 4428. | 4770. |
85 | 1463. | 4716. | 4702. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 978 | 978 | 978 |
|
5 | 966 | 978 | 987 | 93 |
15 | 925 | 957 | 984 | 271 |
25 | 845 | 912 | 974 | 421 |
35 | 731 | 847 | 946 | 529 |
45 | 588 | 760 | 888 | 579 |
55 | 429 | 651 | 807 | 569 |
65 | 274 | 539 | 728 | 518 |
75 | 141 | 437 | 629 | 436 |
85 | 43 | 300 | 460 | 307 |
90 | 26 | 251 | 409 |
|
95 | 24 | 222 | 384 | 232 |
105 | 18 | 147 | 275 | 156 |
115 | 12 | 82 | 150 | 81 |
125 | 8 | 44 | 71 | 38 |
135 | 6 | 24 | 39 | 18 |
145 | 6 | 13 | 22 | 8 |
155 | 5 | 5 | 11 | 3 |
165 | 5 | 3 | 3 | 1 |
175 | 5 | 3 | 2 | 0 |
180 | 3 | 3 | 3 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
785 | 13.8 | 18.4 | |
1314 | 23.1 | 30.8 | |
2462 | 43.2 | 57.8 | |
3723 | 65.3 | 87.4 | |
469 | 8.2 | 11.0 | |
507 | 8.9 | 11.9 | |
533 | 9.4 | 12.5 | |
538 | 9.4 | 12.6 | |
4261 | 74.8 | 100.0 |
Model No. ST4WA254120PG
LER = FP - 62.7 IW - 105.1 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.83
Report Number: G2005354
Catalog Number: ST4WA254120SO
Lamps: F54T5 HO
Luminaire: Sealatron, enclosed industrial with 25% high impact DR acrylic lens for wet/damp locations.
Ballast: B254PUNVD
Report is based on 4400 Lumens per lamp. Efficiency: 74.8%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
|
|
| ||
Spacing Criteria: |
|
| 1.2 |
|
| 1.5 | |||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 77 | 72 | 68 | 64 | 61 | 59 | 60 | 57 | 55 |
02 | 69 | 62 | 56 | 55 | 50 | 47 | 51 | 47 | 44 |
03 | 62 | 53 | 46 | 48 | 42 | 38 | 44 | 40 | 36 |
04 | 57 | 47 | 40 | 42 | 36 | 32 | 39 | 34 | 30 |
05 | 52 | 41 | 34 | 37 | 31 | 27 | 35 | 30 | 26 |
06 | 48 | 37 | 30 | 33 | 28 | 23 | 31 | 26 | 22 |
07 | 44 | 33 | 27 | 30 | 25 | 20 | 28 | 23 | 20 |
08 | 41 | 30 | 24 | 28 | 22 | 18 | 26 | 21 | 17 |
09 | 38 | 28 | 21 | 25 | 20 | 16 | 24 | 19 | 16 |
10 | 36 | 25 | 19 | 23 | 18 | 15 | 22 | 17 | 14 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 5489. | 6321. | 6462. |
55 | 4968. | 6253. | 6461. |
65 | 4024. | 6097. | 6743. |
75 | 2832. | 7059. | 7858. |
85 | 1800. | 7996. | 7411. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1413 | 1413 | 1413 |
|
5 | 1391 | 1414 | 1434 | 135 |
15 | 1338 | 1403 | 1449 | 396 |
25 | 1237 | 1362 | 1447 | 626 |
35 | 1093 | 1288 | 1433 | 802 |
45 | 909 | 1188 | 1359 | 899 |
55 | 681 | 1019 | 1220 | 886 |
65 | 420 | 811 | 1090 | 786 |
75 | 194 | 699 | 1018 | 688 |
85 | 55 | 496 | 693 | 480 |
90 | 26 | 387 | 568 |
|
95 | 38 | 454 | 679 | 423 |
105 | 26 | 259 | 547 | 291 |
115 | 13 | 87 | 202 | 101 |
125 | 0 | 47 | 70 | 37 |
135 | 0 | 28 | 41 | 18 |
145 | 0 | 13 | 27 | 8 |
155 | 0 | 6 | 10 | 1 |
165 | 0 | 0 | 0 | 0 |
175 | 0 | 0 | 0 | 0 |
180 | 0 | 0 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1157 | 13.2 | 17.6 | |
1960 | 22.3 | 29.8 | |
3745 | 42.6 | 56.9 | |
5699 | 64.8 | 86.6 | |
815 | 9.3 | 12.4 | |
852 | 9.7 | 13.0 | |
879 | 10.0 | 13.4 | |
880 | 10.0 | 13.4 | |
6579 | 74.8 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: ST4WA232120SOR‡
ST |
|
|
|
|
|
|
| A | ||
|
|
|
|
|
|
|
|
|
|
|
Sealatron | Fixture Length: | Wet/Damp |
| A=50% DR | ||||||
Enclosed | 4=48" |
| Location |
| Acrylic Crepe | |||||
Industrial | 8=96" |
| W= Wet |
| Lens | |||||
Fluorescent |
|
|
|
| Location |
|
|
| ||
|
|
|
|
|
|
|
|
|
D = Damp
Location
‡No product change. New Catalog Number Designation.
Number of |
| Lamp/Fixture | ||
Lamps |
| Length/Watts: | ||
in Width: | 32 | = 32W | T8 4' Length | |
1=1 Lamp | ||||
28 | = 28W | T5 4' Length | ||
1 Lamp in Tandem | ||||
54 | = 54W | T5 4' Length | ||
96" Unit | 59SL = 59W | SL T8, 8' Length | ||
2=2 Lamp | 86HO = 86W | T8, 380mA, |
2 Lamp in Tandem | 8' Length | |
96" Unit | ||
(1 or 2 Lamps in Tandem | ||
| ||
| for 8' Fixtures) | |
| (Nominal 48") |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: |
|
|
|
| ||||
120, 277 or |
|
|
|
| ||||
|
|
|
| |||||
|
|
| ||||||
|
|
|
| BALLAST: | ||||
|
|
|
|
|
|
| <20THD | |
1 | & 2 Lamp Elec. T8 | SO * | ||||||
| O4 * | |||||||
1 | & 2 Lamp 28W Elec. T5 | – | ||||||
1 | & 2 Lamp 28W Elec. T5 | – | ||||||
1 | & 2 Lamp 54W Elec. T5 | – | ||||||
| – | |||||||
| LOL T8 dimming | PS |
OPTIONS:
Add
appropriate
suffix to
<10THD catalog no.,
HI * ie: (R)
H4 *
PI †
PG †† PG †† PV ††
–
Options/Accessories
Water Tight Kits: One installed each end of fixture. For additional kits, order Catalog
Number: STW DC2.
Electrical/Wiring Options: Consult factory.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.
Suffix: R. One per ballast. Suffix: B.
Fusing: Internal
Top Mounting Bracket: Order Catalog Number: STW TOP BRACKET.
Other dimming options. Consult Factory.
*Instant Start Standard
† Instant Start (120, 277)
†† Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use HI, H4 Ballast Code.
Specifications
Materials: Inner Chassis parts are
Lens: Molded,
Latches:
Finish: Inner chassis
Specifications (continued)
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Job Information | Type: |
|
|
Lightolier | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
Copyright 2006 Lightolier | Section7/Folio |