Lightolier C6E17OVW specifications Lums, Rcr, Candlepower Distribution, Angle, Wall

Page 2

Calculite® HID Downlight C6E17OVW

Page 2 of 2

6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam

70W ED17 PHILIPS COATED METAL HALIDE LAMP-3K. LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

CANDLEPOWER DISTRIBUTION

625

60°

1,250

1,875

2,500

30°

ANGLE

MEAN CP

LUMS.

0

2543

 

5

2498

238

10

2444

 

15

2470

698

20

2462

 

25

2345

1058

30

1990

 

35

1373

860

40

742

 

45

264

249

50

19

 

55

3

6

60

1

 

65

0

0

70

0

 

75

0

0

80

0

 

85

0

0

90

0

 

LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

20520

 

CEILING

 

 

 

80%

 

 

 

70%

 

 

50%

 

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

307

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

 

70

50

30

10

 

50

10

 

50

10

 

50

10

 

0

 

65

 

0

 

 

 

 

 

 

 

 

75

 

0

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

.65

.65

.65

.65

 

.63

.63

 

.61

.61

 

.58

.58

 

.55

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

1

 

.62

.61

.60

.59

 

.60

.58

 

.58

.56

 

.56

.54

 

.52

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

2

 

.60

.57

.55

.54

 

.56

.53

 

.55

.52

 

.53

.51

 

.49

 

0-30

1993

34.98

64.12

 

3

 

.57

.54

.52

.50

 

.53

.49

 

.52

.49

 

.51

.48

 

.46

 

 

4

 

.55

.51

.48

.46

 

.50

.46

 

.49

.45

 

.48

.45

 

.44

 

0-40

2854

50.07

91.78

 

 

 

 

 

 

 

 

5

 

.52

.48

.45

.43

 

.47

.43

 

.46

.42

 

.46

.42

 

.41

 

0-60

3109

54.55

99.99

 

 

 

 

 

 

 

 

6

 

.50

.45

.42

.40

 

.45

.40

 

.44

.40

 

.43

.40

 

.39

 

0-90

3109

54.56

100.00

 

7

 

.47

.43

.40

.38

 

.42

.37

 

.41

.37

 

.41

.37

 

.36

 

40-90

255

4.48

8.22

 

8

 

.45

.40

.37

.35

 

.40

.35

 

.39

.35

 

.39

.34

 

.34

 

60-90

0

0

0.01

 

9

 

.42

.37

.34

.32

 

.37

.32

 

.37

.32

 

.36

.32

 

.31

 

90-180

0

0

0

 

10

 

.40

.35

.32

.30

 

.35

.30

 

.34

.30

 

.34

.30

 

.29

 

 

 

 

 

 

 

 

 

 

 

0-180

3109

54.56

100.00

 

 

 

 

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

**EFFICIENCY = 54.6% SC = 1.0

CERTIFIED TEST REPORT NO. 2540FR, DATE: NOV 8, 2003 S/MH = 1.2

COMPUTED BY LSI PROGRAM **TEST-LITE**

100W ED17 PHILIPS COATED METAL HALIDE LAMP-3K LUMEN RATING = 8500 LMS. ELECTRONIC BALLAST, CL FINISH REFLECTOR

CANDLEPOWER DISTRIBUTION

875

1,750

2,625

3,500

 

ANGLE

MEAN CP

LUMS.

 

0

36

30

 

5

3549

338

 

10

3446

 

 

15

3421

968

 

20

3365

 

60°

25

3154

1445

 

30

2817

 

 

35

2083

1284

 

40

1192

 

 

45

448

417

 

50

68

 

 

55

19

25

 

60

8

 

 

65

5

5

 

70

2

 

 

75

0

1

 

80

0

 

 

85

0

0

30°

90

0

 

LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

34835

 

CEILING

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

55

 

1782

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

 

50

10

50

10

0

 

65

 

658

 

 

 

 

75

 

0

 

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

.63

.63

.63

.63

.61

.61

 

.59

.59

.56

.56

.53

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

1

 

.60

.59

.58

.56

.58

.56

 

.55

.54

.54

.52

.50

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

2

 

.57

.55

.53

.52

.54

.51

 

.53

.50

.51

.49

.47

 

0-30

2751

32.37

61.37

 

3

 

.55

.52

.50

.48

.51

.47

 

.50

.47

.49

.46

.44

 

 

4

 

.52

.49

.46

.44

.48

.44

 

.47

.43

.46

.43

.42

 

0-40

4034

47.47

90.01

 

 

 

 

 

5

 

.50

.46

.43

.41

.45

.41

 

.44

.40

.44

.40

.39

 

0-60

4477

52.67

99.88

 

 

 

 

 

6

 

.48

.43

.40

.38

.43

.38

 

.42

.38

.41

.38

.37

 

0-90

4482

52.74

100

 

7

 

.45

.40

.38

.35

.40

.35

 

.39

.35

.39

.35

.34

 

40-90

447

5.27

9.99

 

8

 

.43

.38

.35

.33

.37

.33

 

.37

.33

.37

.32

.32

 

60-90

5

0.06

0.12

 

9

 

.40

.35

.32

.30

.35

.30

 

.35

.30

.34

.30

.29

 

90-180

0

0

0

 

10

 

.38

.33 .30 .28

.33

.28

 

.32

.28

.32

.28

.27

 

0-180

4482

52.74

100

 

 

 

 

LUMINAIRE INPUT WATTS =

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 52.7% ** SC = 1.1

CERTIFIED TEST REPORT NO. 2338FR, DATE: OCT 19, 2003 S/MH = 1.2

COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Image 2
Contents Frame-In Kit FeaturesOptions and Accessories ElectricalRCR Candlepower DistributionLums Angle