VidPro J150 manual Installation Notes, Port Flanges, Wrong Correct

Page 2
Capscrew
(128110235)

Installation - Notes

Port Flanges

Description

part number

• Allow 1” minimum clearance

 

 

 

 

 

 

Nut - 10mm

(188010200)

 

 

 

 

 

 

around machine for cooling

 

 

 

 

 

 

Washer - 10mm

(194010210)

 

 

 

 

 

 

purposes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The relief valve must be

 

 

 

 

 

 

Flange

(508030207)

 

 

 

 

 

 

 

 

installed before starting the

 

 

 

 

 

 

Gasket

(526071201)

 

 

 

 

 

 

compressor. Reduce the set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure by 1psi for each 2000 ft. of

 

 

 

 

 

 

Bolt - 10 X 50mm

(128010250)

 

 

 

 

 

 

operating altitude above sea level.

 

 

 

 

 

 

• Mount the relief valve horizontally or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pointed down to prevent water ingress.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wrong

correct

 

• Do not exceed recommended drive line

 

angle

Check valve must be mounted after the relief valve.

Air line size from discharge pipework to manlid must be at

least 1” I.D. for adequate unloading rates.

 

Shaft

• Ensure bolt head is placed down into the port recess when

25mm dia.

installing port flanges.

 

 

8mm key

• The compressor can be mounted on any of its 4

 

 

 

mounting faces as shown see Fig 2.

Lockwasher

 

 

 

 

(194010210)

 

 

Mounting Foot

 

 

(507003202)

Spacer

 

 

(516020202)

Drive Line Specifications

Do not force end yokes or drive flange onto the compressor or PTO shaft.

Use a tube type balanced PTO drive shaft, parallel with the PTO output shaft axis within 2° to ensure vibration-free running. The maximum driveline angle

is 10°.

Be sure U-joint yokes are in phase ( see Cauton note )

10° max.

Parallel

within 2°

The mounting bolt pattern for the mounting foot is a square pattern typical on each end. This will allow the mounting foot to be located so that the inlet and the outlet can be on the top, bottom, right side or left side.

Port Flange and Mtg

Foot installation

Fig 2

Image 2
Contents Installation Check List Arrow points to suction portWrong Correct Installation NotesPort Flanges Important Notes Routine MaintenanceOperation Hydraulic Drive OperationPage Bill of Material Safety Precautions Warranty Syltone INDUSTRIES, LLC