TROUBLE-SHOOTING TIPS.
Issue: Support Arm Assembly has prob- lems sliding, or handle is too “loose” or too “tight”.
Solution: Remove any debris from beam slots.
To adjust the tension of the bolt, keep handle in the down position, back nut off, adjust bolt tension and
Issue: “T” Track or “T” slot on Baserail is damaged.
Solution: File track or slot with flat file to remove burr/bump.
Issue: Saw is unstable when the “Toolmount Handles” are put in the unlock position to remove saw.
Solution: Loosen the Toolmount Beam fasteners (to the saw or Toolmount) and
•
•For sliding miter saws, sliding and lock- ing the saw motor & blade to an alternate position during removal and installation should sufficiently stabilize the saw/tool- mount unit.
Issue: Saw has rubber foot pads on the saw base that make tool mount installation difficult.
Solution: Remove rubber foot pads
If necessary on some saws. Toolmount handle can be positioned under this cavity.
Saw Base. (Side view)
Foot pads
Issue: Work support is not horizontal or parallel with the saw table or other support.
Solution: Change angle by placing 5/16’’ washer between the support beam and “T’.
Support Beam
“T”
Washer
IMPORTANT SAFETY INSTRUCTIONS FOR USING THIS UNIVERSAL WORKSTATION
1.Read the Universal Workstation instruction manual
2.This Universal Workstation is designed to be used with Hitachi (C8FB2, C10FCB, C10FS, C10FSB, C10FCE, C10FCH, C10FSH, C12LCH, C12FCH, C12LC, C12LDH, C12FDH), Bosch (3915, 3912, 4412), Delta (MS150, 36.075, 36.225,
3.The Miter Saw should be firmly mounted to the Universal Workstation per the instruction manual.
4.After mounting the Miter Saw to the Universal Workstation, align, position and balance the Miter Saw.
5.Before use, verify that all Universal Workstation parts are free from damage and/ or deformity.
6.Before use, verify that all parts or components of the Universal Workstation are properly installed.
7.Before use, swing open each of the legs until the brass pin clicks, locking the legs in posi- tion.
8.When mounting the Miter Saw to the Universal Workstation, make sure that the tool mount handles are in the “UNLOCK” posi- tion, so the tool mount will engage with the main beam. Be sure to hold the saw until it is secured to prevent it from falling off the main beam. Handles should then be tightened.
9.Before operating the Miter Saw, confirm that the tool mount handles on both sides of this Universal Workstation are firmly tightened ensuring that the Miter Saw is securely mounted to the Workstation.
10.When removing the Miter Saw from the Universal Workstation, loosen the tool mount handles until they rotate to the “UNLOCK”” position. Hold the Miter Saw firmly to pre- vent the saw from falling off the main beam. Carefully remove the Miter Saw.
11.Disconnect the power plug from the power outlet when mounting or dismounting the Miter Saw to the Universal Workstation.
12.Do not modify the Universal Workstation in any manner or use the Universal Workstation for any purpose other than is stated in these instructions.
13.Do not sit or stand on the Universal Workstation. Do not place, hang, or install anything on the Universal Workstation other than a Miter Saw.
14.Always use this universal workstation on a level surface. Do not use it on uneven or unstable surfaces.
15.Before operating the mounted Miter Saw, read the Miter Saw instruction manual care- fully.
16.Because cut material may cause the work- station to become unbalanced, always be sure the material is supported properly. Also, if the piece being cut is placed far beyond the work support, workstation legs on the opposite side may suddenly be lifted up due to weight imbalance. To prevent this from occurring, hold the opposite side firmly before cutting.
Customer Service 508-677-4130
10 INSTRUCTION MANUAL | TracRac Inc. 994 Jefferson Street, Fall River, MA |