Bryant 575A installation instructions Dimensions, Ð2Ð

Page 2

 

UNIT W/

UNIT W/

 

 

WEIGHT (WITH ALUMINUM-FIN COIL)

 

 

 

WEIGHT (WITH COPPER-FIN COIL)

 

 

UNIT

ALUMINUM-FIN

COPPER-FIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575A

COIL

COIL

Std Unit

 

Corner W

Corner X

Corner Y

Corner Z

Std Unit

Corner W

Corner X

Corner Y

 

Corner Z

 

Dim. A

Dim. B

Dim. A

Dim. B

Lb

Kg

 

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

 

Lb

Kg

090

1 -8

1 -5

1 -91¤2

1 -43¤4

540

245

 

132

60

100

45

133

60

175

80

608

276

160

73

117

53

142

64

 

189

86

[508.0]

[431.8]

[546.0]

[425]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1. Dimensions in [ ] are in millimeters.

2. Center of Gravity. See chart for dimensions.

3. Direction of air¯ow.

4.Minimum clearance (local codes or jurisdiction may prevail):

a.Bottom to combustible surfaces, 0 in. (0 mm)

b.Outdoor coil, for proper air¯ow, 36 in. (914 mm) one side, 12 in. (305 mm) the other. The side getting the greater clearance is optional.

c.Overhead, 60 in. (1524 mm) to assure proper outdoor-fan operation.

d.Between units, control box side, 42 in. (1067 mm) per National Electrical Code (NEC).

e.Between unit and ungrounded surfaces, control box side, 36 in. (914 mm) per NEC.

f.Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in. (1067 mm) per NEC.

5.With the exception of the clearance for the outdoor coil as stated in note 4b, a removable fence or barricade requires no clearance.

6.Units may be installed on combustible ¯oors made from wood or Class A, B, or C roof covering material.

7.Vertical center of gravity is approximately 40% of total unit height.

ELECTRICAL CONNECTIONS

CONNECTION SIZES

AA

13¤8

Dia. [35] Field Power Supply Hole

BB

 

2 Dia. [51] Power Supply Knockout

CC

21¤2

Dia. [64] Power Supply Knockout

DD

7¤8

Dia. [22] Field Control Wiring Hole

 

SERVICE VALVE CONNECTIONS

 

 

 

 

 

 

 

UNIT

 

 

SUCTION

 

LIQUID

575A090

 

 

11¤8 [28.6]

 

1¤2 [12.7]

Fig. 2 Ð Dimensions

Ð2Ð

Image 2
Contents Safety Considerations Important Ð Read Before InstallingContents InstallationDimensions Ð2ÐRigging Physical DataII. RIG and Mount the Unit MountingIII. Complete Refrigerant Piping Connections Typical Piping Diagram, 575A/524A-H Ð5ÐÐ6Ð Accessory Electric HeatIV. Make Electrical Connections Ð7Ð Accessory Electric Heater DataElectrical Data II. Evacuate and Dehydrate Field Control WiringSTART-UP Preliminary Checks III. Refrigerant and OIL ChargeCooling IV. Refrigerant Service PortsSequence of Operation HeatingVI. Checking Cooling and Heating Control Operation VII. MalfunctionService Cleaning Outdoor CoilIV. Compressor Removal III. Outdoor FAN Adjustment FigFan Motor Bearings Troubleshooting CHART, Heating Cycle Troubleshooting CHART, Cooling Cycle Controls Preliminary InformationOutdoor Unit Indoor UnitStart-Up

575A specifications

The Bryant 575A is a prominent model in Bryant's lineup of heating, ventilation, and air conditioning (HVAC) systems, known for its reliability and efficiency. Designed with advanced technologies and innovative features, the Bryant 575A is an excellent choice for both residential and light commercial applications.

One of the standout features of the Bryant 575A is its impressive energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that significantly surpasses the minimum standards, the 575A helps homeowners reduce their energy bills while maintaining optimal comfort levels. The system employs variable-speed technology, allowing for precise temperature control and enhanced humidity management. This ensures that the indoor environment remains comfortable year-round, regardless of outdoor conditions.

Incorporating advanced refrigerant management, the Bryant 575A utilizes environmentally friendly R-410A refrigerant. This refrigerant not only minimizes ozone depletion potential but also enhances the overall performance of the system, allowing for efficient heat exchange and quick temperature adjustments. The system's efficiency is further optimized by its multi-stage cooling capabilities, which allow it to adapt to varying cooling loads and maintain consistent indoor temperatures.

The Bryant 575A is built with reliability in mind, featuring durable construction and quality components designed to withstand the rigors of daily use. Its compact design makes it easy to install in various settings, and its low profile ensures it can fit into tight spaces without compromising performance. Additionally, the system is designed for quiet operation, making it an ideal choice for residential areas where noise may be a concern.

Another significant aspect of the Bryant 575A is its compatibility with Bryant's intelligent thermostat technology. The system can seamlessly integrate with smart home setups, allowing homeowners to control their HVAC systems remotely via smartphone apps or home automation systems. This convenience not only enhances user experience but also contributes to energy savings by allowing for more precise control over heating and cooling schedules.

In summary, the Bryant 575A embodies the blend of efficiency, reliability, and advanced technology, making it a top choice for those seeking a high-performance HVAC solution. With features designed to optimize comfort and energy use, the Bryant 575A stands out as a strong contender in the competitive HVAC market.