Wiring Diagram
|
| Switch |
| Black | Motor Lead |
|
| Over Load |
| White | Motor Lead |
|
| Motor |
Power Cord | Green | Grounding Wire |
|
Troubleshooting
Problem |
| Possible Cause |
| Remedy |
|
|
|
|
|
|
|
|
|
|
Snipe | 1. | Dull knives | 1. | Replace knives per instructions (See |
(Gouging at ends of |
|
|
| “Replacing Knives” section) |
board) | 2. | Inadequate support of long boards | 2. | Support long boards |
| 3. | Lumber not butted properly | 3. | Butt end to end each piece of stock as |
|
|
|
| boards pass through planer |
| 4. | Extensions misaligned | 4. | Adjust extension supports |
|
|
|
|
|
Fuzzy Grain | 1. | Planing wood with a high moisture | 1. | Remove high moisture content from wood by |
|
| content |
| drying |
|
|
|
|
|
Torn Grain | 1. | Too heavy a cut | 1. | Review “Depth of Cut” section |
| 2. | Knives cutting against grain | 2. | Review “Feeding the Work” section |
| 3. | Dull knives | 3. | Replace knives per instructions |
|
|
|
|
|
Rough Raised Grain | 1. | Dull knives | 1. | Replace knives per instructions |
| 2. | Too heavy a cut | 2. | Review “Depth of Cut” |
| 3. | Moisture content too high | 3. | Dry the wood or use dried wood |
|
|
|
|
|
Uneven Depth Cut | 1. | Blade projection not uniform | 1. | Check that end of knife is fully seated in the |
Side to Side |
|
|
| cutter head. |
|
|
|
|
|
Cutter head Eleva- | 1. | Elevation screws dirty | 1. | Clean and lubricate elevation screws |
tion Adjusts with Dif- | 2. | Gears or screws worn | 2. | Replace |
ficulty | 3. | Friction between casing and covers | 3. | Clean, lubricate |
|
|
|
|
|
Board Thickness | 1. | Indicator not set correctly | 1. | Adjust indicator/securely tighten |
Does Not Match | 2. | Knife projection incorrect | 2. | Set knife projection correctly (See “Replac- |
Depth of Cut Scale |
|
|
| ing Knives” section). |
|
|
|
|
|
Chain Jumping | 1. | Sprockets worn | 1. | Replace sprockets |
| 2. | Chain worn | 2. | Replace chain |
|
|
|
|
|
Motor does not start | 1. | Switch malfunction | 1. | Have a qualified electrician replace the ON/ |
|
|
|
| OFF switch. |
| 2. | Overload protector tripped | 2. | Turn power switch off. When planer tempera- |
|
|
|
| ture adequately cools (allow |
|
|
|
| press overload protector reset button. |
| 3. | Supply fuse opens | 3. | Replace fuse with a 15 amp time delay fuse, |
|
|
|
| or circuit breaker. |
| 4. | Brushes worn | 4. | See “Maintenance” section, ”Changing |
|
|
|
| Brushes |
| 5. | Other | 5. | Get authorized service. |
|
|
|
|
|
Dust chute is | 1. | Build up of resin under dust chute | 1. | Clean dust chute and exhaust area. |
blocked | 2. | Large debris | 2. | Clear debris. |
|
|
|
|
|
18